Advances in tandem mass spectrometry (MS/MS) acquisition rate have steadily led to increased performance in shotgun proteomics experiments. To that end, contemporary mass spectrometers are outfitted with multiple analyzers allowing for the simultaneous collection of survey (MS1) and MS/MS spectra. In the latest generation Orbitrap hybrid, MS/MS scans can be acquired at a high rate using the dual cell linear ion trap analyzer, all while the next precursor is being dissociated in a collision cell and a MS1 scan is occurring in the Orbitrap. Often overlooked in these experiments is that the ion trap scan duration is highly variable and dependent upon precursor mass. Here, we examine the use of various static mass-to-charge ratio scan ranges for ion trap MS/MS acquisition and determine performance relative to conventional dynamic mass-to-charge ratio range scanning. We demonstrate that a fixed mass-to-charge ratio scan range can generate 12% more MS/MS scans and more unique peptide identifications as compared to the standard dynamic approach, respectively.

Research Organization:
University of Wisconsin, Madison, WI (United States)
Sponsoring Organization:
USDOE Office of Science - SC, Biological and Environmental Research (BER) (United States)
DOE Contract Number:
SC0018409
OSTI ID:
23129552
Report Number(s):
OSTIID--1569267
Journal Information:
Analytical Chemistry, Journal Name: Analytical Chemistry Journal Issue: 20 Vol. 91; ISSN 0003-2700
Country of Publication:
United States
Language:
English

Similar Records

Maximizing Tandem Mass Spectrometry Acquisition Rates for Shotgun Proteomics
Journal Article · Wed Sep 11 00:00:00 EDT 2019 · Analytical Chemistry · OSTI ID:1569267

Imaging MS Methodology for More Chemical Information in Less Data Acquisition Time Utilizing a Hybrid Linear Ion Trap-Orbitrap Mass Spectrometer
Journal Article · Sun Nov 14 23:00:00 EST 2010 · Analytical Chemistry · OSTI ID:1024884

Dynamic range of mass accuracy in LTQ orbitrap hybrid mass spectrometer
Journal Article · Sat Jul 15 00:00:00 EDT 2006 · Journal of the American Society for Mass Spectrometry · OSTI ID:22774035