Title: An analysis of the equivalent dose calculation for the remainder tissues

Journal Article · · Health Physics
;  [1]
  1. Institut fuer Stranhlenschutz, Neuherberg (Germany)

In the 1990 Recommendations of the International Commission on Radiological Protection, the risk-weighted quantity {open_quotes}effective dose equivalent{close_quotes} was replaced by a similar quantity, {open_quotes}effective dose.{close_quotes} Among other alterations, the selection of the organs and tissues contributing to the risk-weighted quantity and their respective weighting factors were changed, including a modified definition of the so-called {open_quotes}remainder.{close_quotes} Close consideration of this latter definition shows that is causes certain ambiguities are unexpected effects which are dealt with in the following. For several geometries of external photon irradiation, the numerical differences of two possible methods of evaluating the remainder dose from the doses to ten single organs, namely as arithmetic mean or as mass weighted average, are assessed. It is shown that deviation from these averaging procedures, as prescribed for these cases where a remainder organ receives a higher dose than an organ with a specified weighting factor, cause discontinuities in the energy dependence of the remainder dose and, consequently, also non-additivity of this quantity. These problems are discussed, and it is shown that, although the numerical consequences for the calculation of the effective dose are small, this unsatisfactory situation needs clarification. One approach might be to abolish some of the ICRP guidance relating to the appropriate tissue weighting factors for the remainder tissues and organs and to make other guidance more precise. 14 refs., 12 figs., 2 tabs.

Sponsoring Organization:
USDOE
OSTI ID:
230687
Journal Information:
Health Physics, Vol. 69, Issue 3; Other Information: PBD: Sep 1995
Country of Publication:
United States
Language:
English

Similar Records

The effect of gender and remainder on effective dose equivalent
Conference · Fri Jan 01 00:00:00 EST 1988 · Transactions of the American Nuclear Society; (USA) · OSTI ID:230687

A comparison of the angular dependence of effective dose and effective dose equivalent
Journal Article · Sat Jun 01 00:00:00 EDT 1996 · Health Physics · OSTI ID:230687

Influence of organs in the ICRP's remainder on effective dose equivalent computed for diagnostic radiation exposures
Journal Article · Sat Apr 01 00:00:00 EST 1989 · Health Phys.; (United States) · OSTI ID:230687