skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Comparison of subchannel and averaged channel thermal-hydraulic descriptions on coupled pin-by-pin neutronic calculations

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:23042914
; ;  [1]
  1. Department of Energy Engineering Universidad Politecnica de Madrid - UPM, Jose Gutierrez Abascal, 2, Madrid, Spain, 28006 (Spain)

Best-estimate transient analysis of Light Water Reactors (LWRs) requires high accuracy code systems solving neutronics (NK), thermal-hydraulics (TH) and thermal-mechanics to model the core behavior. For long time, nodal diffusion methods for solution of the transport equation using assembly size computational meshes have been applied neglecting the details within the fuel assembly, or using 'pin power reconstruction' techniques to predict those details. Moreover, the multiphysics analysis has been commonly performed coupling those neutronic diffusion methods to thermal-hydraulic system codes using a nodalization of several fuel assemblies per computational node without taking into account the effects that this type of averaging can have on the results obtained. This paper presents the work accomplished with the coupled system COBAYA4/CTF for a preliminary analysis of the effect of the different accuracy levels in the NK and TH domain. COBAYA4 is a neutronic code able to solve the diffusion equation at two resolution levels, nodal and pin by pin (PbP). CTF is a thermo-hydraulic code able to solve the coolant conservation equations also at two levels, channel (fuel assembly averaged solution) and sub-channel (real cooling channel) level. The coupled system COBAYA4/CTF is used through SALOME platform, i.e. SALOME is the software able to map conveniently the NK and TH meshes. This coupling allows combining different resolution levels for NK and TH problems. Therefore, the study of the effect of using different resolutions for the NK and TH nodalizations has been performed applying the system to a fuel assembly with selected boundary conditions. (authors)

OSTI ID:
23042914
Journal Information:
Transactions of the American Nuclear Society, Vol. 115; Conference: 2016 ANS Winter Meeting and Nuclear Technology Expo, Las Vegas, NV (United States), 6-10 Nov 2016; Other Information: Country of input: France; 8 refs.; available from American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 (US); ISSN 0003-018X
Country of Publication:
United States
Language:
English