skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: ITER Port Interspace Pressure Calculations

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:22991885
;  [1]
  1. Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN, 37831-6167 (United States)

The ITER ('the way' in Latin) project in Cadarache, France, will operate the largest tokamak ever built to demonstrate the physical and technical feasibility of nuclear fusion as an energy source. The ITER vacuum vessel is equipped with 50 access ports. Each port has an opening in the bio-shield that communicates with a dedicated port cell. During tokamak operation, the bio-shield opening must be closed with a concrete plug to shield the radiation coming from the plasma. This port plug separates the port cell into a port interspace (between vacuum vessel closure lid and port plug) on the inner side and a port cell on the outer side. This paper presents calculations of pressures and temperatures in the ITER port interspace after a double-ended guillotine break (DEGB) of a pipe in the tokamak cooling water system (TCWS). It is assumed that the DEGB occurs during the worst possible conditions-during water baking operation, with water at 523 K (250 deg. C) and 4.4 MPa. These conditions are more severe than during normal tokamak operation with the water at 398 K (125 deg. C) and 2 MPa. Two computer codes are employed in these calculations: RELAP5-3D Version 4.2.1 to calculate blowdown releases from the pipe break, and MELCOR, Version 1.8.6 to calculate pressures and temperatures in the port interspace. A sensitivity study has been performed to optimize the maximum peak pressure in the port interspace volume of ITER. The optimum case was for a labyrinth area (FL131) of 0.5 m{sup 2} and a relief panel (FL135) kept open after the first cycle. This case keeps the pressure in the port interspace under 150 kPa and the temperatures under 385 K. (authors)

OSTI ID:
22991885
Journal Information:
Transactions of the American Nuclear Society, Vol. 114, Issue 1; Conference: Annual Meeting of the American Nuclear Society, New Orleans, LA (United States), 12-16 Jun 2016; Other Information: Country of input: France; 3 refs.; Available from American Nuclear Society - ANS, 555 North Kensington Avenue, La Grange Park, IL 60526 United States; ISSN 0003-018X
Country of Publication:
United States
Language:
English

Similar Records

ITER Port Interspace Pressure Calculations
Conference · Fri Jan 01 00:00:00 EST 2016 · OSTI ID:22991885

Integration of the ITER Tokamak C-model with the Building Model
Journal Article · Sat Jul 01 00:00:00 EDT 2017 · Transactions of the American Nuclear Society · OSTI ID:22991885

Neutronics Analysis for ITER Diagnostic Generic Upper Port Plug
Journal Article · Sat Jul 01 00:00:00 EDT 2017 · Transactions of the American Nuclear Society · OSTI ID:22991885