Efficiency optimization control of AC induction motors: Initial laboratory results. Final report, January 1992-September 1994
Technical Report
·
OSTI ID:229290
A fuzzy logic, energy optimizing controller has been developed to improve the efficiency of motor/drive combinations which operate at varying load and speed conditions. The energy optimizer is complemented by a sensorless speed controller which maintains motor shaft revolutions per minute (RPM) to produce constant output power. Efficiency gains of from 1 to 20% are obtained from laboratory demonstration with commercial motors and drives. Motor shaft RPM is controlled to within 0.5%. The energy optimizing controller used for vector control adjustable speed drives is complemented by a torque pulsation control scheme to rapidly damp vibrations.
- Research Organization:
- Research Triangle Inst., Durham, NC (United States)
- OSTI ID:
- 229290
- Report Number(s):
- PB--96-153424/XAB
- Country of Publication:
- United States
- Language:
- English
Similar Records
Fuzzy-logic control of AC induction motors
Improving ac motor efficiency with fuzzy logic energy optimizer
Fuzzy logic motor control for pollution prevention and improved energy efficiency. Report for October 1992-August 1993