Title: MR elastography of liver at 3 Tesla: comparison of gradient-recalled echo (GRE) and spin-echo (SE) echo-planar imaging (EPI) sequences and agreement across stiffness measurements

Journal Article · · Abdominal Radiology (Online)
 [1];  [2];  [1];  [3];
  1. NYU Langone Health, Department of Radiology (United States)
  2. Siemens Healthcare GmbH (Germany)
  3. Siemens Healthineers (United States)

Purpose: To compare 2D gradient-recalled echo (GRE) and 2D spin-echo (SE) echo-planar imaging (EPI) MR elastography (MRE) for measurement of hepatic stiffness in adult patients with known or suspected liver disease at 3 Tesla. Materials and methods: Three hundred and eighty-seven consecutive patients underwent MRE of the liver at 3 Tesla with 2D-GRE and 2D-SE-EPI sequences. ‘Mean liver stiffness (LS)’ calculated by averaging 3 ROIs in the right lobe, ‘Maximum LS’ calculated by an ROI in the right lobe; and ‘Freehand LS’ calculated by an ROI in the entire liver were measured by two independent readers. Inter-observer and inter-class variability in stiffness measurements were assessed. Stiffness values were correlated with degree of liver fibrosis (METAVIR scores) in 97 patients who underwent biopsy. The diagnostic performance was compared by a receiver-operating characteristic analysis. Results: The technical failure rate was 2.8% for 2D-SE-EPI (11/387) and 4.1% for 2D-GRE (16/387, 9 had R{sub 2}* > 80 s{sup −1} indicating iron overload). There is high reproducibility for both GRE and SE-EPI variants (ICC = 0.84–0.94 for both GRE and SE-EPI MRE). The highest sensitivity, specificity, and accuracy of differentiating mild fibrosis (F0–F2) from advanced fibrosis (F3–F4) are 0.84 (GRE Freehand measurement), 0.92 (GRE Maximum stiffness measurement), and 0.88 (GRE Freehand measurement), respectively. Conclusions: High intra-class correlation and intra-reader correlation are seen on measured hepatic stiffness for both 2D-GRE and 2D-SE-EPI MRE. 2D-SE-EPI has lower failure rate. Diagnostic performance of both sequences is equivalent, with highest sensitivity for 2D-GRE Freehand stiffness measurement, and highest specificity 2D-GRE Maximum stiffness measurement.

OSTI ID:
22923012
Journal Information:
Abdominal Radiology (Online), Vol. 44, Issue 5; Other Information: Copyright (c) 2019 Springer Science+Business Media, LLC, part of Springer Nature; Country of input: International Atomic Energy Agency (IAEA); ISSN 2366-0058
Country of Publication:
United States
Language:
English

Similar Records

Magnetic resonance elastography SE-EPI vs GRE sequences at 3T in a pediatric population with liver disease
Journal Article · Fri Mar 01 00:00:00 EST 2019 · Abdominal Radiology (Online) · OSTI ID:22923012

Can MR elastography be used to measure liver stiffness in patients with iron overload?
Journal Article · Tue Jan 15 00:00:00 EST 2019 · Abdominal Radiology (Online) · OSTI ID:22923012

Evaluation of Liver Stiffness After Radioembolization by Real-Time ShearWave™ Elastography: Preliminary Study
Journal Article · Sat Aug 15 00:00:00 EDT 2015 · Cardiovascular and Interventional Radiology · OSTI ID:22923012