The American Society of Radiation Oncology has recently recommended the use of radiosurgery to manage brain metastases. For such a recommendation to be implemented in a widespread manner, radiosurgery must be accessible at community radiation therapy facilities. The work presented here describes our clinical experience in the implementation of radiosurgery using a Helical TomoTherapy unit. Helical TomoTherapy is a unique dose-delivery system designed to perform intensity-modulated radiation therapy (IMRT). The system built on the ring-based gantry has the tight machine tolerances required for radiosurgery. A frameless system consisting of a thermoplastic mask and a noninvasive ''stereotactic radiosurgery (SRS)-stereotactic radiotherapy (SRT)'' fixation device is used for patient immobilization. Treatment planning is performed using the TomoHD treatment planning system designed for IMRT. The image-guidance system on the Helical TomoTherapy is used for patient localization. Our clinical experience demonstrated that the radiosurgery procedure can be streamlined as we do for IMRT patients. The treatment time of about 10 minutes is comparable with that for IMRT patients. The same patient-specific quality assurance for IMRT is used for radiosurgery. As demonstrated, SRS using Helical TomoTherapy is not a whole-day event, unlike SRS using other dose-delivery systems or SRS performed in the past.

OSTI ID:
22824204
Journal Information:
Medical Dosimetry, Journal Name: Medical Dosimetry Journal Issue: 3 Vol. 43; ISSN 0958-3947
Country of Publication:
United States
Language:
English

Similar Records

3D treatment planning on helical tomotherapy delivery system
Journal Article · Fri Jun 15 00:00:00 EDT 2018 · Medical Dosimetry · OSTI ID:22824189

A Technique for Stereotactic Radiosurgery Treatment Planning with Helical Tomotherapy
Journal Article · Fri Apr 01 00:00:00 EDT 2011 · Medical Dosimetry · OSTI ID:21486884

Initial Experience With Volumetric IMRT (RapidArc) for Intracranial Stereotactic Radiosurgery
Journal Article · Tue Nov 30 23:00:00 EST 2010 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:21491515