Personnel Qualification and Certification Program in Pressure Decay Leak Testing on the RT-100 Type (B) Cask - 17229
Conference
·
OSTI ID:22794613
- Robatel Technologies, LLC, 5115 Bernard Dr. suite 304, Roanoke, VA 24018 (United States)
The requirements for qualifications and certification of leak test personnel on Type (B) shipping casks have been more clearly defined with the recent release of ANSI N14.5-2014, Leak Tests on Radioactive Packages for Shipment. The latest version creates a standardized approach for qualifying and certifying personnel to conduct pre-shipment leakage tests on Type (B) packages. The U.S Nuclear Regulatory Commission (NRC) is currently updating the Regulatory Guide R.G 7.4, Leakage Tests on Packages for shipment of Radioactive Material, to endorse ANSI N14.5-2014. According to ANSI N14.5-2014, leakage testing shall be performed in accordance with written procedures by qualified and certified personnel in accordance with the requirements of ASNT SNT-TC-1A-2006, Recommended Practice for Personnel Qualification and Certification in Nondestructive Testing. This is a significant modification to the old standard, ANSI N14.5-1997, which simply states that pressure leak testing shall be conducted by trained and certified personnel without reference to any specific certification standards or regulations. SNT-TC-1A published by the American Society for Nondestructive Testing (ASNT) has several advantages to employers; namely, it allows for a Limited NDT Level II certification program. Limited certifications are especially valuable for personnel who possess limited experience and wish to become a certified Limited NDT Level II in a specific technique on a specific cask using a specific procedure and equipment. Robatel Technologies recently developed a comprehensive qualification and training program based on the recommendations of SNT-TC-1A for Exelon Corporation to certify their employees to a Limited NDT Level II in Pressure Decay Leak Testing on the RT-100 Cask. The project scope included the development of a training and qualification program (Written practice), writing a pressure decay leak test procedure, the design of a pressure decay leak test manifold, and the delivery of classroom training. The written practice outlines the requirements to ensure that personnel participating in the program have the necessary qualification, experience, and training to become certified in the leak test method. The program will give Exelon the liberty to conduct their own leak testing on the RT- 100 without the need to rely on outside resources for leak testing. When fully implemented, the program is expected to improve productivity and eliminate schedule delays, along with substantial economic benefits. Following the appropriate standards and industry best practices, the project was successfully completed and scheduled to be fully implemented by Exelon's Nuclear Stations by the end of 2016. (authors)
- Research Organization:
- WM Symposia, Inc., PO Box 27646, 85285-7646 Tempe, AZ (United States)
- OSTI ID:
- 22794613
- Report Number(s):
- INIS-US--19-WM-17229
- Country of Publication:
- United States
- Language:
- English
Similar Records
Personnel training and certification
Leakage Rate Testing Considerations and Implementation of ANSI N 14.5-2014 Standard within EnergySolutions Type (B) cask fleet - 18629
Nondestructive Evaluation Quality Procedure: Personnel Qualification and Certification Radiographic Testing-Levels I& II
Conference
·
Wed Dec 31 23:00:00 EST 1975
· Am. Soc. Test. Mater., Spec. Tech. Publ.; (United States)
·
OSTI ID:7346442
Leakage Rate Testing Considerations and Implementation of ANSI N 14.5-2014 Standard within EnergySolutions Type (B) cask fleet - 18629
Conference
·
Sun Jul 01 00:00:00 EDT 2018
·
OSTI ID:22977874
Nondestructive Evaluation Quality Procedure: Personnel Qualification and Certification Radiographic Testing-Levels I& II
Technical Report
·
Tue Jul 01 00:00:00 EDT 2003
·
OSTI ID:15004935