A novel linear ion trap mass analyzer was developed using just four elongated planar electrodes, mounted in parallel, and employing an RF potential for ion trapping in the radial and axial directions. Mass analysis was achieved using the mass-selective instability scan with ion ejection in the radial direction. The performance of this new device was characterized in comparison with the 6-electrode rectilinear ion trap (RIT) from which it is derived. The 4-electrode trap gives optimum performance in an asymmetric geometry, just like the original optimized 6-electrode RIT. The strong RF fringing fields at the ends of the RF rods account for axial ion trapping without use of extra electrodes or an axial DC voltage. Field calculations and simulations have been carried out to study the trapping potential inside RITs with various configurations. Demonstrated capabilities include analysis of externally injected ions with mass resolution in excess of 1000 and a mass/charge range of 650 Th as well as tandem mass spectrometry capabilities. The geometric simplicity and performance characteristics of the 4-electrode RIT make it particularly attractive in the development of next generation miniaturized mass spectrometers.
OSTI ID:
22774056
Journal Information:
Journal of the American Society for Mass Spectrometry, Journal Name: Journal of the American Society for Mass Spectrometry Journal Issue: 4 Vol. 17; ISSN 1044-0305; ISSN JAMSEF
Country of Publication:
United States
Language:
English

Similar Records

Co-occurrence of boundary and resonance ejection in a multiplexed rectilinear ion trap mass spectrometer
Journal Article · Sat Jan 14 23:00:00 EST 2006 · Journal of the American Society for Mass Spectrometry · OSTI ID:22774093

Experimental Observation of the Effects of Translational and Rotational Electrode Misalignment on a Planar Linear Ion Trap Mass Spectrometer
Journal Article · Sun Jul 15 00:00:00 EDT 2018 · Journal of the American Society for Mass Spectrometry · OSTI ID:22776892

Simulation of Unidirectional Ion Ejection in an Asymmetric Half-Round Rod Electrode Linear Ion Trap Mass Analyzer
Journal Article · Mon Oct 15 00:00:00 EDT 2018 · Journal of the American Society for Mass Spectrometry · OSTI ID:22776835