Multisource inverse-geometry CT. Part I. System concept and development
- CT Systems and Applications Laboratory, GE Global Research, Niskayuna, New York 12309 (United States)
- Functional Imaging Laboratory, GE Global Research, Niskayuna, New York 12309 (United States)
- School of Integrated Technology, Yonsei University, Incheon 406-840 (Korea, Republic of)
- Mechanical Systems Technologies, GE Global Research, Niskayuna, New York 12309 (United States)
- Design and Development Shops, GE Global Research, Niskayuna, New York 12309 (United States)
- High Energy Physics Laboratory, GE Global Research, Niskayuna, New York 12309 (United States)
- Detector Laboratory, GE Global Research, Niskayuna, New York 12309 (United States)
- High Frequency Power Electronics Laboratory, GE Global Research, Niskayuna, New York 12309 (United States)
- Molecular Imaging and Computed Tomography, GE Healthcare, Waukesha, Wisconsin 53188 (United States)
- Department of Radiology, Stanford University, Stanford, California 94305 (United States)
Purpose: This paper presents an overview of multisource inverse-geometry computed tomography (IGCT) as well as the development of a gantry-based research prototype system. The development of the distributed x-ray source is covered in a companion paper [V. B. Neculaes et al., “Multisource inverse-geometry CT. Part II. X-ray source design and prototype,” Med. Phys. 43, 4617–4627 (2016)]. While progress updates of this development have been presented at conferences and in journal papers, this paper is the first comprehensive overview of the multisource inverse-geometry CT concept and prototype. The authors also provide a review of all previous IGCT related publications. Methods: The authors designed and implemented a gantry-based 32-source IGCT scanner with 22 cm field-of-view, 16 cm z-coverage, 1 s rotation time, 1.09 × 1.024 mm detector cell size, as low as 0.4 × 0.8 mm focal spot size and 80–140 kVp x-ray source voltage. The system is built using commercially available CT components and a custom made distributed x-ray source. The authors developed dedicated controls, calibrations, and reconstruction algorithms and evaluated the system performance using phantoms and small animals. Results: The authors performed IGCT system experiments and demonstrated tube current up to 125 mA with up to 32 focal spots. The authors measured a spatial resolution of 13 lp/cm at 5% cutoff. The scatter-to-primary ratio is estimated 62% for a 32 cm water phantom at 140 kVp. The authors scanned several phantoms and small animals. The initial images have relatively high noise due to the low x-ray flux levels but minimal artifacts. Conclusions: IGCT has unique benefits in terms of dose-efficiency and cone-beam artifacts, but comes with challenges in terms of scattered radiation and x-ray flux limits. To the authors’ knowledge, their prototype is the first gantry-based IGCT scanner. The authors summarized the design and implementation of the scanner and the authors presented results with phantoms and small animals.
- OSTI ID:
- 22689435
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 8 Vol. 43; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
A prototype table-top inverse-geometry volumetric CT system
Inverse-geometry volumetric CT system with multiple detector arrays for wide field-of-view imaging
Multisource inverse-geometry CT. Part II. X-ray source design and prototype
Journal Article
·
Thu Jun 15 00:00:00 EDT 2006
· Medical Physics
·
OSTI ID:20853199
Inverse-geometry volumetric CT system with multiple detector arrays for wide field-of-view imaging
Journal Article
·
Fri Jun 15 00:00:00 EDT 2007
· Medical Physics
·
OSTI ID:20951502
Multisource inverse-geometry CT. Part II. X-ray source design and prototype
Journal Article
·
Mon Aug 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22689436