Practical reconstruction protocol for quantitative {sup 90}Y bremsstrahlung SPECT/CT
Purpose: To develop a practical background compensation (BC) technique to improve quantitative {sup 90}Y-bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) using a commercially available imaging system. Methods: All images were acquired using medium-energy collimation in six energy windows (EWs), ranging from 70 to 410 keV. The EWs were determined based on the signal-to-background ratio in planar images of an acrylic phantom of different thicknesses (2–16 cm) positioned below a {sup 90}Y source and set at different distances (15–35 cm) from a gamma camera. The authors adapted the widely used EW-based scatter-correction technique by modeling the BC as scaled images. The BC EW was determined empirically in SPECT/CT studies using an IEC phantom based on the sphere activity recovery and residual activity in the cold lung insert. The scaling factor was calculated from 20 clinical planar {sup 90}Y images. Reconstruction parameters were optimized in the same SPECT images for improved image quantification and contrast. A count-to-activity calibration factor was calculated from 30 clinical {sup 90}Y images. Results: The authors found that the most appropriate imaging EW range was 90–125 keV. BC was modeled as 0.53× images in the EW of 310–410 keV. The background-compensated clinical images had higher image contrast than uncompensated images. The maximum deviation of their SPECT calibration in clinical studies was lowest (<10%) for SPECT with attenuation correction (AC) and SPECT with AC + BC. Using the proposed SPECT-with-AC + BC reconstruction protocol, the authors found that the recovery coefficient of a 37-mm sphere (in a 10-mm volume of interest) increased from 39% to 90% and that the residual activity in the lung insert decreased from 44% to 14% over that of SPECT images with AC alone. Conclusions: The proposed EW-based BC model was developed for {sup 90}Y bremsstrahlung imaging. SPECT with AC + BC gave improved lesion detectability and activity quantification compared to SPECT with AC only. The proposed methodology can readily be used to tailor {sup 90}Y SPECT/CT acquisition and reconstruction protocols with different SPECT/CT systems for quantification and improved image quality in clinical settings.
- OSTI ID:
- 22689394
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 9 Vol. 43; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Monte Carlo simulation of PET and SPECT imaging of {sup 90}Y
Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging
{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction
Journal Article
·
Wed Apr 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22413520
Implications of CT noise and artifacts for quantitative {sup 99m}Tc SPECT/CT imaging
Journal Article
·
Tue Apr 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22250840
{sup 90}Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction
Journal Article
·
Wed Jul 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22581383