Suppression of a prebreakdown current as a method to increase a static breakdown voltage in pseudospark switches

Conference ·
OSTI ID:226884
; ;  [1]
  1. High Current Electronics Inst., Tomsk (Russian Federation); and others

Considerable interest has recently been generated in a new type of high-voltage low-pressure switching device, often named the pseudospark switch. One of the problems for such switches is to increase the static breakdown voltage since this parameter is very important in itself and. besides, determines the ability for the switch to operate in high frequency mode. In parallel with other methods, a so-called blocking electrodes are used to solve the above problem. The action of the blocking electrodes, is related to suppression a prebreakdown current in the main gap of the switch. Additional results in support of the current suppression concept are presented here.

OSTI ID:
226884
Report Number(s):
CONF-950749--
Country of Publication:
United States
Language:
English

Similar Records

Investigation of the effect of blocking potential on the static breakdown voltage and discharge initiation in pseudospark switches
Journal Article · Thu Jun 01 00:00:00 EDT 1995 · IEEE Transactions on Plasma Science · OSTI ID:118949

Trigger devices for pseudospark switches
Journal Article · Thu Jun 01 00:00:00 EDT 1995 · IEEE Transactions on Plasma Science · OSTI ID:118946

Influence of crossed electric and magnetic fields upon the breakdown voltage and prebreakdown current in vacuum
Journal Article · Thu May 01 00:00:00 EDT 1980 · J. Appl. Phys.; (United States) · OSTI ID:5314144