skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Whole-brain Irradiation Field Design: A Comparison of Parotid Dose

Journal Article · · Medical Dosimetry
; ; ; ; ; ; ; ;  [1];  [1]
  1. Department of Radiation Oncology, Columbia University Medical Center, 622 West 168th Street, BNH B-11, New York, NY 10032 (United States)

Whole-brain radiation therapy (WBRT) plays an important role in patients with diffusely metastatic intracranial disease. Whether the extent of the radiation field design to C1 or C2 affects parotid dose and risk for developing xerostomia is unknown. The goal of this study is to examine the parotid dose based off of the inferior extent of WBRT field to either C1 or C2. Patients treated with WBRT with either 30 Gy or 37.5 Gy from 2011 to 2014 at a single institution were examined. Parotid dose constraints were compared with Radiation Therapy Oncology Group (RTOG) 0615 nasopharyngeal carcinoma for a 33-fraction treatment: mean <26 Gy, volume constraint at 20 Gy (V20) < 20 cc, and dose at 50% of the parotid volume (D50) < 30 Gy. Biologically effective dose (BED) conversions with an α/β of 3 for normal parotid were performed to compare with 10-fraction and 15-fraction treatments of WBRT. The constraints are as follows: mean < BED 32.83 Gy, V15.76 (for 10-fraction WBRT) or V17.35 (for 15-fraction WBRT) < 20 cc, and D50 < BED 39.09 Gy. Nineteen patients treated to C1 and 26 patients treated to C2 were analyzed. Comparing WBRT to C1 with WBRT to C2, the mean left, right, and both parotids' doses were lower when treated to C1. Converting mean dose to BED{sub 3}, the parotid doses were lower than BED{sub 3} constraint of 32.83 Gy: left (30.12 Gy), right (30.69 Gy), and both parotids (30.32 Gy). V20 to combined parotids was lower in patients treated to C1. When accounting for fractionation of WBRT received, the mean corrected V20 volume was less than 20 cc when treating to C1. D50 for C1 was lower than C2 for the left parotid, right parotid, and both parotids. BED{sub 3} conversion for the mean D50 of the left, right, and both parotids was less than 39.09 Gy. In conclusion, WBRT to C1 limits parotid dose, and parotid dose constraints are achievable compared with inferior border at C2. A possible mean parotid dose constraint with BED{sub 3} should be less than 32.83 Gy.

OSTI ID:
22685196
Journal Information:
Medical Dosimetry, Vol. 42, Issue 2; Other Information: Copyright (c) 2017 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0958-3947
Country of Publication:
United States
Language:
English