skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Angular oversampling with temporally offset layers on multilayer detectors in computed tomography

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4948505· OSTI ID:22685136
;  [1]
  1. Department of Physics, Section for Medical Imaging, Royal Institute of Technology, AlbaNova University Center, SE-106 91 Stockholm (Sweden)

Purpose: Today’s computed tomography (CT) scanners operate at an increasingly high rotation speed in order to reduce motion artifacts and to fulfill the requirements of dynamic acquisition, e.g., perfusion and cardiac imaging, with lower angular sampling rate as a consequence. In this paper, a simple method for obtaining angular oversampling when using multilayer detectors in continuous rotation CT is presented. Methods: By introducing temporal offsets between the measurement periods of the different layers on a multilayer detector, the angular sampling rate can be increased by a factor equal to the number of layers on the detector. The increased angular sampling rate reduces the risk of producing aliasing artifacts in the image. A simulation of a detector with two layers is performed to prove the concept. Results: The simulation study shows that aliasing artifacts from insufficient angular sampling are reduced by the proposed method. Specifically, when imaging a single point blurred by a 2D Gaussian kernel, the method is shown to reduce the strength of the aliasing artifacts by approximately an order of magnitude. Conclusions: The presented oversampling method is easy to implement in today’s multilayer detectors and has the potential to reduce aliasing artifacts in the reconstructed images.

OSTI ID:
22685136
Journal Information:
Medical Physics, Vol. 43, Issue 6; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Nonrigid registration-based coronary artery motion correction for cardiac computed tomography
Journal Article · Sun Jul 15 00:00:00 EDT 2012 · Medical Physics · OSTI ID:22685136

Multithreaded cardiac CT
Journal Article · Sat Jul 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:22685136

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22685136