Purpose: Adaptive dose-painting-by-number (DPbN) requires a dose-response-mapping (DRM) obtained early in the treatment course. To obtain DRM, voxel-by-voxel tumor dose response needs to be quantified. Our recent study has demonstrated that voxel-by-voxel radio-sensitivity of patient tumor can be determined using tumor-metabolic-ratio measured early during the treatment using FDG-PET images. In this study, the measurements were utilized to construct tumor metabolic control probability (TMCP) and DRM for DPbN. Methods: FDG-PET/CT images of 18 HN cancer patients obtained pre- and weekly during the treatment were used. Spatial parametric images of tumor-metabolic-ratio (dSUV) were constructed following voxel-by-voxel deformable image registration. Each voxel value in dSUV was a function of baseline SUV and delivered dose. Utilizing all values of dSUV in the controlled tumor group at the last treatment week, a cut-off function between the baseline SUV and dSUV was formed, and applied in early treatment days on dSUV of all tumors to model the TMCP. At the treatment week k, TMCP was constructed with respect to the tumor voxel dSUV appeared at the week using the maximum likelihood estimation for all dose levels, and used for DRM construction. Results: TMCPs estimated in the week 2 & 3 have D{sub 50}=11.1∼47.6Gy; γ{sub 50}=0.55∼0.92 respectively with respect to dSUV=0.3∼1.2. The corresponding DRM between tumor voxel dSUV and the expected treatment dose has sigmoid shape. The expected treatment dose are 26∼40Gy (for 95% TMCP) for high sensitive tumor voxels with dSUV=0.3∼0.5; and 65∼110Gy for low sensitive tumor voxels with the dSUV>1.0 depending on the time of the estimation. Conclusion: TMCP can be constructed voxel-by-voxel in human tumor using multiple FDG-PET imaging obtained in early treatment days. TMCP provides a potential quantitative objective of tumor DRM for DPbN to plan the best dose, escalate or de-escalate, in tumor adaptively based on its own radio-sensitivity.

OSTI ID:
22679307
Journal Information:
Medical Physics, Vol. 43, Issue 6; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

SU-F-J-59: Assessment of Dose Response Distribution in Individual Human Tumor
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:22679307

Adaptive Dose Painting by Numbers for Head-and-Neck Cancer
Journal Article · Fri Jul 15 00:00:00 EDT 2011 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22679307

SU-D-201-02: Prediction of Delivered Dose Based On a Joint Histogram of CT and FDG PET Images
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22679307