SU-F-T-201: Acceleration of Dose Optimization Process Using Dual-Loop Optimization Technique for Spot Scanning Proton Therapy

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4956338· OSTI ID:22648818
;  [1]
  1. Hitachi, Ltd. Research and Development Group, Hitachi-shi, Ibaraki-ken (Japan)

Purpose: The purpose was to demonstrate a developed acceleration technique of dose optimization and to investigate its applicability to the optimization process in a treatment planning system (TPS) for proton therapy. Methods: In the developed technique, the dose matrix is divided into two parts, main and halo, based on beam sizes. The boundary of the two parts is varied depending on the beam energy and water equivalent depth by utilizing the beam size as a singular threshold parameter. The optimization is executed with two levels of iterations. In the inner loop, doses from the main part are updated, whereas doses from the halo part remain constant. In the outer loop, the doses from the halo part are recalculated. We implemented this technique to the optimization process in the TPS and investigated the dependence on the target volume of the speedup effect and applicability to the worst-case optimization (WCO) in benchmarks. Results: We created irradiation plans for various cubic targets and measured the optimization time varying the target volume. The speedup effect was improved as the target volume increased, and the calculation speed increased by a factor of six for a 1000 cm3 target. An IMPT plan for the RTOG benchmark phantom was created in consideration of ±3.5% range uncertainties using the WCO. Beams were irradiated at 0, 45, and 315 degrees. The target’s prescribed dose and OAR’s Dmax were set to 3 Gy and 1.5 Gy, respectively. Using the developed technique, the calculation speed increased by a factor of 1.5. Meanwhile, no significant difference in the calculated DVHs was found before and after incorporating the technique into the WCO. Conclusion: The developed technique could be adapted to the TPS’s optimization. The technique was effective particularly for large target cases.

OSTI ID:
22648818
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 43; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Intensity Modulated Proton Beam Radiation for Brachytherapy in Patients With Cervical Carcinoma
Journal Article · Sat Nov 30 23:00:00 EST 2013 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22278267

A GPU-accelerated and Monte Carlo-based intensity modulated proton therapy optimization system
Journal Article · Sun Dec 14 23:00:00 EST 2014 · Medical Physics · OSTI ID:22403167

SU-E-T-477: IMPT Vs. VMAT: A Treatment Planning Study for High-Risk Prostate Cancer
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22548518