Title: Evaluation of a Bioabsorbable Self-Expandable Vein Stent-Base Made of Poly(l-lactide) In Vitro and In Vivo

Journal Article · · Cardiovascular and Interventional Radiology
 [1]; ;  [2];  [3];  [4]
  1. Purdue University, Weldon School of Biomedical Engineering (United States)
  2. Cook Research Incorporated (United States)
  3. Institut für Radiologie, Kantonsspital Winterthur (Switzerland)
  4. William Cook Europe (Denmark)

PurposeThis study was designed to evaluate performance and tissue response to a self-expandable bioabsorbable vein stent-base cut from a tube with enhanced stiffness and strength in vitro and in vivo.MethodsA diamond-shaped stent-base was cut from a sequential biaxially strained poly(l-lactide) (PLLA) tube for optimized performance. The performance of the stent-base was evaluated in a finite element analysis model, and validation was attempted in vitro through a cyclic flat-plate compression and radial force measurement. The performance of the stent-base was tested in vivo using 3 sheep with 2 implants each for 2 and 3½ weeks, respectively.ResultsIn vitro the stent-base showed an elliptical deformation but no fractures. In vivo the stent-base showed adequate radial force and no migration. All implanted stent-bases showed multiple fractures not only at the predicted stress zones but at all connecting points. Fragments of the caudal stent-base stayed in the vein wall indicating sufficient tissue coverage to avoid embolization of the fractured stent pieces, whereas fragments from the cranial device remaining were few. Neointima formation was confirmed histologically at 2 and 3½ weeks.ConclusionA bioabsorbable self-expandable stent-base made from PLLA for large veins seems feasible, but over time, the PLLA used in this study appears too stiff and lacks the sufficient flexibility to move with the vena cava, causing multiple fractures.

OSTI ID:
22645352
Journal Information:
Cardiovascular and Interventional Radiology, Vol. 40, Issue 1; Conference: BSIR 2016: Britisch Society of Interventional Radiology 2016 annual meeting, Manchester (United Kingdom), 15-17 Nov 2016; Other Information: Copyright (c) 2017 Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE); http://www.springer-ny.com; Country of input: International Atomic Energy Agency (IAEA); ISSN 0174-1551
Country of Publication:
United States
Language:
English

Similar Records

Multiplicity of morphologies in poly (L-lactide) bioresorbable vascular scaffolds
Journal Article · Mon Sep 26 00:00:00 EDT 2016 · Proceedings of the National Academy of Sciences of the United States of America · OSTI ID:22645352

Efficacy and Safety of Endovascular Intervention for the Management of Primary Entire-Inferior Vena Cava Occlusion
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Cardiovascular and Interventional Radiology · OSTI ID:22645352

Blocking of the Hepatic Vein Outflow by Neointima Covering a Wallstent Across a Membranous Stenosis of the Inferior Vena Cava
Journal Article · Mon Nov 15 00:00:00 EST 1999 · Cardiovascular and Interventional Radiology · OSTI ID:22645352