Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Initial performances of first undulator-based hard x-ray beamlines of NSLS-II compared to simulations

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4952874· OSTI ID:22608387
Commissioning of the first X-ray beamlines of NSLS-II included detailed measurements of spectral and spatial distributions of the radiation at different locations of the beamlines, from front-ends to sample positions. Comparison of some of these measurement results with high-accuracy calculations of synchrotron (undulator) emission and wavefront propagation through X-ray transport optics, performed using SRW code, is presented.
OSTI ID:
22608387
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1741; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English