Title: Construction and performance of combustion beamline at NSRL

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4952860· OSTI ID:22608373
; ; ; ; ; ;  [1];  [2]
  1. National Synchrotron Radiation Laboratory(NSRL), University of Science and Technology of China, Hefei 230029 (China)
  2. China Academy of Engineering and Physics, Mianyang 621900 (China)

An undulator-based VUV beamline BL03U is constructed at the National Synchrotron Radiation Laboratory. Optical design and performance test results are presented in this paper. The monochromator is a Czerny–Turner configuration with a toroidal collimating mirror, two plane gratings, and a toroidal focusing mirror. Plane gratings with line densities of 200 and 400 l/mm are used to cover the photon energy range of 5–21 eV. A gas absorption spectrum is used to evaluate the beamline performance. The photon energy resolving power (E/ΔE) of the beamline is approximately 3900 at 7.3 eV for the 200 l/mm grating and 4200 at 14.6 eV for the 400 l/mm grating. The photon flux is approximately 5×10{sup 12} photons/s/300 mA at energy of 10 eV.

OSTI ID:
22608373
Journal Information:
AIP Conference Proceedings, Vol. 1741, Issue 1; Conference: SRI2015: 12. international conference on synchrotron radiation instrumentation, New York, NY (United States), 6-10 Jul 2015; Other Information: (c) 2016 Author(s); Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

SAMRAI: A novel variably polarized angle-resolved photoemission beamline in the VUV region at UVSOR-II
Journal Article · Sat May 15 00:00:00 EDT 2010 · Review of Scientific Instruments · OSTI ID:22608373

New SRC APPLE ll Variable Polarization Beamline
Journal Article · Sat Dec 31 00:00:00 EST 2011 · Nuclear Instruments and Methods in Physics Research, Section A · OSTI ID:22608373

TGM-to-SGM conversion at NSLS beamline U7A: Recyclying of beamline components
Journal Article · Sun Sep 01 00:00:00 EDT 1996 · Review of Scientific Instruments · OSTI ID:22608373