High voltage breakdown phenomena in RF window, electron gun and RF cavities in 250 kW CW C band Klystron and their preventive measures
- Department of Physics, University of Rajasthan, Jaipur (India)
The paper describes voltage break down phenomenon and preventive measures in components of 250 KW CW, C band Klystron under development at CEERI Pilani. The Klystron operates at a beam voltage of 50 kV and delivers 250 kW RF power at 5 GHz frequency. The Klystron consists of several key components and regions, which are subject to high electrical stress. The most important regions of electrical breakdown are electron gun, the RF ceramic window and output cavity gap area. In the critical components voltage breakdown considered at design stage by proper gap and other techniques. All these problems discussed, as well as solution to alleviate this problem. The electron gun consists basically of cathode, BFE and anode. The cathode is operated at a voltage of 50 kV. In order to maintain the voltage standoff between cathode and anode a high voltage alumina seal and RF window have been designed developed and successfully used in the tube. (author)
- Research Organization:
- Bhabha Atomic Research Centre, Mumbai (India); Indian Vacuum Society, Mumbai (India)
- OSTI ID:
- 22597154
- Country of Publication:
- United States
- Language:
- English
Similar Records
Breakdown phenomena in high power klystrons
Breakdown phenomena in high-power klystrons
DESIGN OF A DC/RF PHOTOELECTRON GUN.
Conference
·
Mon Feb 29 23:00:00 EST 1988
·
OSTI ID:5214270
Breakdown phenomena in high-power klystrons
Journal Article
·
Thu Nov 30 23:00:00 EST 1989
· IEEE (Institute of Electrical and Electronics Engineers) Micro; (USA)
·
OSTI ID:6778765
DESIGN OF A DC/RF PHOTOELECTRON GUN.
Conference
·
Mon May 12 00:00:00 EDT 2003
·
OSTI ID:15006697