Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

In-vacuum sensors for the beamline components of the ITER neutral beam test facility

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4959954· OSTI ID:22596525

Embedded sensors have been designed for installation on the components of the MITICA beamline, the prototype ITER neutral beam injector (Megavolt ITER Injector and Concept Advancement), to derive characteristics of the particle beam and to monitor the component conditions during operation for protection and thermal control. Along the beamline, the components interacting with the particle beam are the neutralizer, the residual ion dump, and the calorimeter. The design and the positioning of sensors on each component have been developed considering the expected beam-surface interaction including non-ideal and off-normal conditions. The arrangement of the following instrumentation is presented: thermal sensors, strain gages, electrostatic probes including secondary emission detectors, grounding shunt for electrical currents, and accelerometers.

OSTI ID:
22596525
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 11 Vol. 87; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

Preliminary design of electrostatic sensors for MITICA beam line components
Journal Article · Sun Feb 14 23:00:00 EST 2016 · Review of Scientific Instruments · OSTI ID:22483037

Benchmark of numerical tools simulating beam propagation and secondary particles in ITER NBI
Journal Article · Wed Apr 08 00:00:00 EDT 2015 · AIP Conference Proceedings · OSTI ID:22391443

Diagnostics of the ITER neutral beam test facility
Journal Article · Tue Feb 14 23:00:00 EST 2012 · Review of Scientific Instruments · OSTI ID:22063909