Title: The multi-spectral line-polarization MSE system on Alcator C-Mod

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4959793· OSTI ID:22596511
 [1];  [2]
  1. Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)
  2. Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States)

A multi-spectral line-polarization motional Stark effect (MSE-MSLP) diagnostic has been developed for the Alcator C-Mod tokamak wherein the Stokes vector is measured in multiple wavelength bands simultaneously on the same sightline to enable better polarized background subtraction. A ten-sightline, four wavelength MSE-MSLP detector system was designed, constructed, and qualified. This system consists of a high-throughput polychromator for each sightline designed to provide large étendue and precise spectral filtering in a cost-effective manner. Each polychromator utilizes four narrow bandpass interference filters and four custom large diameter avalanche photodiode detectors. Two filters collect light to the red and blue of the MSE emission spectrum while the remaining two filters collect the beam pi and sigma emission generated at the same viewing volume. The filter wavelengths are temperature tuned using custom ovens in an automated manner. All system functions are remote controllable and the system can be easily retrofitted to existing single-wavelength line-polarization MSE systems.

OSTI ID:
22596511
Journal Information:
Review of Scientific Instruments, Vol. 87, Issue 11; Other Information: (c) 2016 Author(s); Country of input: International Atomic Energy Agency (IAEA); ISSN 0034-6748
Country of Publication:
United States
Language:
English

Cited By (3)

The multi-spectral imaging diagnostic journal October 2018
Optimal MSE polarisation angle and q-profile estimation using Kalman filters and the plasma simulator RAPTOR journal February 2019
Experimental and synthetic measurements of polarized synchrotron emission from runaway electrons in Alcator C-Mod journal July 2019

Similar Records

The multi-spectral line-polarization MSE system on Alcator C-Mod
Journal Article · Wed Aug 17 00:00:00 EDT 2016 · Review of Scientific Instruments · OSTI ID:22596511

Robotic calibration of the motional Stark effect diagnostic on Alcator C-Mod
Journal Article · Thu May 15 00:00:00 EDT 2014 · Review of Scientific Instruments · OSTI ID:22596511

Simulations of beam-emission spectroscopy on Alcator C-Mod (abstract)
Journal Article · Mon Jan 01 00:00:00 EST 2001 · Review of Scientific Instruments · OSTI ID:22596511