Title: Technical Note: Confirming the prescribed angle of CT localizer radiographs and c-arm projection acquisitions

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4940124· OSTI ID:22579857
;  [1];  [2]
  1. Department of Human Oncology, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)
  2. Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

Purpose: Accurate CT radiograph angle is not usually important in diagnostic CT. However, there are applications in radiation oncology and interventional radiology in which the orientation of the x-ray source and detector with respect to the patient is clinically important. The authors present a method for measuring the accuracy of the tube/detector assembly with respect to the prescribed tube/detector position for CT localizer, fluoroscopic, and general radiograph imaging using diagnostic, mobile, and c-arm based CT systems. Methods: A mathematical expression relating the x-ray projection of two metal BBs is related to gantry angle. Measurement of the BBs at a prescribed gantry (i.e., c-arm) angle can be obtained and using this relation the prescribed versus actual gantry angle compared. No special service mode or proprietary information is required, only access to projection images is required. Projection images are available in CT via CT localizer radiographs and in the interventional setting via fluorography. Results: The technique was demonstrated on two systems, a mobile CT scanner and a diagnostic CT scanner. The results confirmed a known issue with the mobile scanner and accurately described the CT localizer angle of the diagnostic system tested. Conclusions: This method can be used to quantify gantry angle, which is important when projection images are used for procedure guidance, such as in brachytherapy and interventional radiology applications.

OSTI ID:
22579857
Journal Information:
Medical Physics, Vol. 43, Issue 2; Other Information: (c) 2016 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

TU-AB-204-00: Advances in Cone-Beam CT and Emerging Applications
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22579857

TU-AB-204-01: Advances in C-Arm CBCT for Brain Perfusion Imaging
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22579857

TU-AB-204-02: Advances in C-Arm CBCT for Cardiac Interventions
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22579857