Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Penalized maximum likelihood reconstruction for x-ray differential phase-contrast tomography

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4938067· OSTI ID:22579803
 [1];  [2];  [3];  [4];  [5]
  1. Research Laboratories, Philips GmbH Innovative Technologies, Hamburg D-22335 (Germany)
  2. Lehrstuhl für Biomedizinische Physik, Physik-Department und Institut für Medizintechnik, Technische Universität München, Garching D-85748 (Germany)
  3. Department of Radiology, Technische Universität München, Munich D-80333 (Germany)
  4. Lehrstuhl für Biomedizinische Physik, Physik-Department und Institut für Medizintechnik, Technische Universität München, Garching D-85748, Germany and Department of Radiology, Technische Universität München, Munich D-80333 (Germany)
  5. Research Laboratories, Philips GmbH Innovative Technologies, Hamburg D-22335, Germany and Institute for Advanced Study, Technische Universität München, Garching D-85748 (Germany)

Purpose: The purpose of this work is to propose a cost function with regularization to iteratively reconstruct attenuation, phase, and scatter images simultaneously from differential phase contrast (DPC) acquisitions, without the need of phase retrieval, and examine its properties. Furthermore this reconstruction method is applied to an acquisition pattern that is suitable for a DPC tomographic system with continuously rotating gantry (sliding window acquisition), overcoming the severe smearing in noniterative reconstruction. Methods: We derive a penalized maximum likelihood reconstruction algorithm to directly reconstruct attenuation, phase, and scatter image from the measured detector values of a DPC acquisition. The proposed penalty comprises, for each of the three images, an independent smoothing prior. Image quality of the proposed reconstruction is compared to images generated with FBP and iterative reconstruction after phase retrieval. Furthermore, the influence between the priors is analyzed. Finally, the proposed reconstruction algorithm is applied to experimental sliding window data acquired at a synchrotron and results are compared to reconstructions based on phase retrieval. Results: The results show that the proposed algorithm significantly increases image quality in comparison to reconstructions based on phase retrieval. No significant mutual influence between the proposed independent priors could be observed. Further it could be illustrated that the iterative reconstruction of a sliding window acquisition results in images with substantially reduced smearing artifacts. Conclusions: Although the proposed cost function is inherently nonconvex, it can be used to reconstruct images with less aliasing artifacts and less streak artifacts than reconstruction methods based on phase retrieval. Furthermore, the proposed method can be used to reconstruct images of sliding window acquisitions with negligible smearing artifacts.

OSTI ID:
22579803
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 1 Vol. 43; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Penalized weighted least-squares image reconstruction for positron emission tomography
Journal Article · Wed Jun 01 00:00:00 EDT 1994 · IEEE Transactions on Medical Imaging (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:7082286

SU-E-J-133: Autosegmentation of Linac CBCT: Improved Accuracy Via Penalized Likelihood Reconstruction
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22494145

Reconstruction of truncated TCT and SPECT data from a right-angle dual-camera system for myocardial SPECT
Conference · Mon Dec 30 23:00:00 EST 1996 · OSTI ID:513268