TU-F-CAMPUS-T-05: Dose Escalation to Biological Tumor Volumes of Prostate Cancer Patients Using Gold Nanoparticles
- Department of Physics and Applied Physics, Medical Physics Program, University of Massachusetts Lowell (United States)
- Department of Radiation Oncology, Dana Farber Cancer Insitute, Brigham and Women’s Hospital, Harvard Medical, Boston, MA (United States)
Purpose: Studies have shown that radiation boosting could help reduce prostate cancer (PCa) recurrence. Biological tumor volumes (BTV) are a high priority for such radiation boosting. The purpose of this study is to investigate the potential of radiation boosting of real patient BTVs using gold nanoparticles (GNP) released from gold-loaded brachytherapy spacers (GBS) during brachytherapy. Methods: The BTVs of 12 patients having prostate adenocarcinoma identified with positron emission tomography (PET) and CT scanner using C-11 labeled tracer [11C]acetate were investigated. The initial GNP concentration and time to achieve a dose enhancement effect (DEF) of 2 was simulated using the freely downloadable software RAID APP. The investigations were carried out for low dose rate (LDR) brachytherapy sources (BTS) described in AAPM Task Group report 43: Cs-131, I-125, and Pd-103. In first case, we used 7 mg/g and 18 mg/g of GNP initial concentrations to estimate the time needed for released GNP to achieve a DEF of 2 for the different BTS, and compare with clinically relevant treatment times. In second case, we calculated the initial concentration of GNPs needed to achieve a DEF of 2 during the time the BTS would typically deliver 50%, 70% and 90% of the total dose. Results: For an initial concentration of 18 mg/g, when using Cs-131, and Pd-103, a DEF of 2 could only be achieved for BTV of 3.3 cm3 and 1 cm3 respectively. Meanwhile a DEF of 2 could be achieved for all 12 BTVs when using I-125. To achieve a DEF of 2 for all patients using Cs-131 and Pd-103, much higher initial concentrations would have to be used than have been typically employed in pre-clinical studies. Conclusion: The I-125 is the most viable BTS that can be employed with GBS to guide dose painting treatment planning for localized PCa.
- OSTI ID:
- 22570059
- Journal Information:
- Medical Physics, Vol. 42, Issue 6; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
- Country of Publication:
- United States
- Language:
- English
Similar Records
MO-AB-BRA-02: Modeling Nanoparticle-Eluting Spacer Degradation During Brachytherapy Application with in Situ Dose-Painting
SU-E-T-333: Towards Customizable Radiotherapy Enhancement (CuRE) for Prostate Cancer Using Cisplatin Nanoparticles