TU-AB-201-10: Novel Conformal Skin Brachytherapy Device
- University of Oklahoma Health Science Center, Oklahoma City, OK (United States)
- East Carolina Univ, Greenville, NC (United States)
Purpose: A novel conformal skin brachytherapy (CSBT) device was developed to provide patient specific treatment for small inoperable lesions and irregular surfaces that are not good candidates for electron external beam, e.g. eyelids, nose, lips, ears, etc. Methods: A prototype was built and tested using radioactive seeds spaced by 1.5 mm attached to a 3D printed template. Seeds were allowed to move independently at treatment surface to conform to target geometry. Beta-emitter Praseodymium-142 (half-life: 19.12 h, average beta energy: 809 keV) and Iodine-125 Model 6711 (half-life: 59.4 days, average gamma energy: 28 keV) seeds were used to test the feasibility of the device in solid water phantom for different prescription depths and surface areas. Percent depth doses and dose profiles were analyzed. MCNPX2.6 Monte Carlo Simulation and Gafchromic EBT3 film measurements were performed for a single Pr-142 seed. Treatment with nineteen I-125 seeds was planned in BrachyVision and measured experimentally for a total dose of 500 cGy at 5.0 mm depth. Results: For a single Pr-142 seed, dose was 500.0 cGy at surface and 17.4 cGy at 5.00 mm. BrachyVision planned and film doses for I-125 seed matrix were 500 cGy and 473.5 cGy at 5 mm depth and 171.0 cGy and 201.0 cGy at 10 mm depth. Total covered surface area for Pr-142 and I-125 were 2.35 mm{sup 2} and 88.24 mm{sup 2} respectively. Profile dose fall-off showed to be very conformal to contact area with 50% of the total surface dose from a single Pr-142 and array of I-125 seeds being deposited at 0.72 mm and 0.65 mm respectively from the central axis. Conclusion: CSBT device provides a high conformal dose to small surfaces. BrachyVision can be used to predict clinical dose distributions for multiple seeds matrix. Different radioactive seeds can be used to suit prescription depth and treatment area.
- OSTI ID:
- 22563021
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
SU-E-T-652: Quantification of Dosimetric Uncertainty of I-125 COMS Eye Plaque
COMS eye plaque brachytherapy dosimetry simulations for {sup 103}Pd, {sup 125}I, and {sup 131}Cs
Two-dimensional dose distribution around a commercial /sup 125/I seed
Journal Article
·
Mon Jun 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22538161
COMS eye plaque brachytherapy dosimetry simulations for {sup 103}Pd, {sup 125}I, and {sup 131}Cs
Journal Article
·
Tue Jul 15 00:00:00 EDT 2008
· Medical Physics
·
OSTI ID:21120858
Two-dimensional dose distribution around a commercial /sup 125/I seed
Journal Article
·
Thu Dec 31 23:00:00 EST 1987
· Med. Phys.; (United States)
·
OSTI ID:5580050