SU-E-T-745: The Use of Electron Dense Materials for Quality Assurance Testing in a Magnetic Field
- University Medical Center Utrecht, Utrecht (Netherlands)
Purpose: Due to the effect of the magnetic field on the dose deposition (skewing the beam), machine quality assurance (QA) tests for the MR-linac (MRI combined with a linear accelerator) need to be redesigned. In this work we focus on the redesign of QA tests that address geometrical accuracy of the system. Methods: Using electron dense materials (e.g. copper in our experiment) the dose kernel is minimized and thereby the effect of the magnetic field on the dose distribution. This approach is supported by Monte-Carlo simulations and can be used in practice with film measurements. Two examples of QA tests are presented: beam profile and star-shot measurements. Results: The novel method was verified by performing both measurements on a conventional linac and the MR-linac with a film that was sandwiched between copper layers. Measurements were compared with a reference setup which was similar to setup used in clinical practice. On a conventional linac the experimental outcome showed good agreement between the reference and the new setup for both QA tests. The results from the MR-linac showed that the symmetry of the beam profile was restored in presence of the copper layers in the setup and that the isocenter size can be determined accurately with the introduced star-shot setup (see supporting material). Conclusion: The use of electron dense materials for QA tests was shown to be a simple and effective method to remove the effects on the dose distribution enabling assessment of geometrical accuracy of a MR-linac system. The use of high dense materials is not limited to the presented QA tests only, but has a broad applicability for beam specific QA tests in presence of a magnetic field.
- OSTI ID:
- 22555113
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
SU-E-J-202: Performance of the Patient QA Systems in a Hybrid MRI-Linac
SU-E-T-514: Simultaneously Determination of Radiation Isocentricity of Gantry, Collimator and Couch Using a Commercial Three-Dimensional Dosimetry QA Apparatus
MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases
Journal Article
·
Mon Jun 15 00:00:00 EDT 2015
· Medical Physics
·
OSTI ID:22499306
SU-E-T-514: Simultaneously Determination of Radiation Isocentricity of Gantry, Collimator and Couch Using a Commercial Three-Dimensional Dosimetry QA Apparatus
Journal Article
·
Sun Jun 01 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22369642
MO-FG-CAMPUS-TeP1-04: Pseudo-In-Vivo Dose Verification of a New Mono-Isocentric Technique for the Treatment of Multiple Brain Metastases
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22653895