SU-E-T-498: Initial Characterization of the New EBT XD Gafchromic Film

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4924860· OSTI ID:22548536
Purpose To assess the dosimetric accuracy of the new EBT XD (eXtended Dose) Gafchromic film and to compare the lateral scan effect between EBT XD and EBT3 film. Methods: All films were exposed in solid water using a 6 MV beam and were analyzed with FilmQA Pro software and an Epson 10000 XL scanner. Calibration was performed using films exposed to 8 known doses from 0–3000 cGy. To assess dosimetric accuracy, a 15×18 cm{sup 2} 60° EDW delivered a dose range of 200–2900 cGy to 4 separate EBT XD films. Comparison to treatment planning system (TPS) predictions was made using a gamma analysis with 2%/2mm passing criteria. To assess the lateral scan effect, 21 × 21 cm{sup 2} open fields delivered doses of 1000, 2000, and 3000 cGy isocentrically to both EBT3 and EBT XD films at 10 cm depth. Films were centered and scanned such that the widest parts of the exposed film extended lateral to the center of the scanner bed in order to maximize the lateral scan effect. Ratios of measured to TPS predicted doses for EBT3 and EBT XD film were calculated at 5 cm and 8 cm lateral from the center of the scanner bed to quantitatively assess the lateral scan effect. Results The average gamma passing rate for the EDW was 98.9% (range 98.7 – 99.1%). EBT XD film exhibited minimal lateral scan effect (<1%) up to 30 Gy. In contrast, EBT3 showed an under-response of 13% and 25% at lateral positions of 5 cm and 8 cm respectively for the 30 Gy exposure. Conclusion EBT XD can accurately measure dose over a wide dynamic range. The non-polarizing structure of its active ingredient essentially eliminates the lateral scan effect up to at least 30 Gy. EBT XD film is therefore well suited for SRS/SBRT verification measurements.
OSTI ID:
22548536
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

Technical Note: Initial characterization of the new EBT-XD Gafchromic film
Journal Article · Thu Oct 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22482341

Technical Note: On GAFChromic EBT-XD film and the lateral response artifact
Journal Article · Sun Feb 14 23:00:00 EST 2016 · Medical Physics · OSTI ID:22579846

SU-F-T-581: The Effect of Scanning Orientation On New EBT-XD Film Using Vidar and Epson Scanners
Journal Article · Wed Jun 15 00:00:00 EDT 2016 · Medical Physics · OSTI ID:22649156