In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)
- Research Organization:
- Institute of Electrical and Electronics Engineers - IEEE, 3 Park Avenue, 17th Floor, New York, N.Y. 10016-5997 (United States)
- OSTI ID:
- 22531314
- Report Number(s):
- ANIMMA--2015-IO-267
- Country of Publication:
- United States
- Language:
- English
Similar Records
Calculated organ doses using Monte Carlo simulations in a reference male phantom undergoing HDR brachytherapy applied to localized prostate carcinoma
Multi-species prostate implant treatment plans incorporating {sup 192}Ir and {sup 125}I using a Greedy Heuristic based 3D optimization algorithm
Influence of phantom material and dimensions on experimental {sup 192}Ir dosimetry
Journal Article
·
Fri Mar 15 00:00:00 EDT 2013
· Medical Physics
·
OSTI ID:22130568
Multi-species prostate implant treatment plans incorporating {sup 192}Ir and {sup 125}I using a Greedy Heuristic based 3D optimization algorithm
Journal Article
·
Wed Feb 14 23:00:00 EST 2007
· Medical Physics
·
OSTI ID:20951036
Influence of phantom material and dimensions on experimental {sup 192}Ir dosimetry
Journal Article
·
Mon Jun 15 00:00:00 EDT 2009
· Medical Physics
·
OSTI ID:22100535