Track-etch dosemeter response to neutrons up to 300 MeV

Conference ·
OSTI ID:225070
; ; ;  [1]; ;  [2]
  1. Los Alamos National Lab., NM (United States)
  2. Science Applications International Corp., Los Alamos, NM (United States)
Electro-chemical and chemical track-etch dosemeters were obtained from commercial suppliers and exposed to neutrons produced at the LANTF WNR white neutron source at 15{degree} with no shielding and filtered by polyethylene blocks of 2.5, 5.1, 10.2, 20.3 and 40.6 cin thickness. The neutron spectrum was determined using calculations. Mean energies from 28 to 300 MeV were produced. Dose was calculated from the NCRP-38 flux-to-dose conversion. The results are compared with NTA film which was exposed in the same configuration. The response of track etch dosimeters was found to reach a minimum and then rise as the average neutron energy increased. The response of the NTA film increased as the neutron energy increased.
Research Organization:
Los Alamos National Lab., NM (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-7405-ENG-36
OSTI ID:
225070
Report Number(s):
LA-UR--96-0307; CONF-960409--3; ON: DE96008146
Country of Publication:
United States
Language:
English