SU-E-T-556: Monte Carlo Generated Dose Distributions for Orbital Irradiation Using a Single Anterior-Posterior Electron Beam and a Hanging Lens Shield

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4924918· OSTI ID:22496271
 [1]; ; ;  [2]
  1. Cincinnati, OH (United States)
  2. University of Cincinnati, Cincinnati, OH (United States)
Purpose: Various cancers of the eye are successfully treated with radiotherapy utilizing one anterior-posterior (A/P) beam that encompasses the entire content of the orbit. In such cases, a hanging lens shield can be used to spare dose to the radiosensitive lens of the eye to prevent cataracts. Methods: This research focused on Monte Carlo characterization of dose distributions resulting from a single A-P field to the orbit with a hanging shield in place. Monte Carlo codes were developed which calculated dose distributions for various electron radiation energies, hanging lens shield radii, shield heights above the eye, and beam spoiler configurations. Film dosimetry was used to benchmark the coding to ensure it was calculating relative dose accurately. Results: The Monte Carlo dose calculations indicated that lateral and depth dose profiles are insensitive to changes in shield height and electron beam energy. Dose deposition was sensitive to shield radius and beam spoiler composition and height above the eye. Conclusion: The use of a single A/P electron beam to treat cancers of the eye while maintaining adequate lens sparing is feasible. Shield radius should be customized to have the same radius as the patient’s lens. A beam spoiler should be used if it is desired to substantially dose the eye tissues lying posterior to the lens in the shadow of the lens shield. The compromise between lens sparing and dose to diseased tissues surrounding the lens can be modulated by varying the beam spoiler thickness, spoiler material composition, and spoiler height above the eye. The sparing ratio is a metric that can be used to evaluate the compromise between lens sparing and dose to surrounding tissues. The higher the ratio, the more dose received by the tissues immediately posterior to the lens relative to the dose received by the lens.
OSTI ID:
22496271
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

An anterior appositional electron field technique with a hanging lens block in orbital radiotherapy: A dosimetric study
Journal Article · Thu Aug 01 00:00:00 EDT 1991 · International Journal of Radiation Oncology, Biology and Physics; (United States) · OSTI ID:5228021

Anterior eye protection with orbital neoplasia
Journal Article · Tue Dec 31 23:00:00 EST 1985 · Int. J. Radiat. Oncol., Biol. Phys.; (United States) · OSTI ID:5732245

Proton radiation therapy for retinoblastoma: Comparison of various intraocular tumor locations and beam arrangements
Journal Article · Mon Jan 31 23:00:00 EST 2005 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:20633067