Title: Study of the choice of the decoupling layout for the ITER ICRH system

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4936519· OSTI ID:22496212

10 decouplers are used to neutralize the mutual coupling effects and to control the current amplitude of the 24 straps array of the ITER ICRH antenna in the case of current drive phasing. In the case of heating phasing only 4 decouplers are active and the array current control needs to act on the ratio between the power delivered by the 4 generators. This ratio is very sensitive to the precise adjustment of the antenna array phasing. The maximum total radiated power capability is then limited when the power of one generator reaches its maximum value. With the addition of four switches all 10 installed decouplers are made active and can act on all mutual coupling effects with equal source power from the 4 generators. With four more switches the current drive phasing could work with a reduced poloidal phasing resulting in a 35% increase of its coupling to the plasma.

OSTI ID:
22496212
Journal Information:
AIP Conference Proceedings, Vol. 1689, Issue 1; Conference: 21. topical conference on radio frequency power in plasmas, Lake Arrowhead, CA (United States), 27-29 Apr 2015; Other Information: (c) 2015 EURATOM; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
Country of Publication:
United States
Language:
English