Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Kinetic instabilities in pulsed operation mode of a 14 GHz electron cyclotron resonance ion source

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4931711· OSTI ID:22482863
; ; ; ;  [1]; ;  [2];  [2]
  1. Department of Physics, University of Jyväskylä, 40500 Jyväskylä (Finland)
  2. Institute of Applied Physics, RAS, 46 Ul‘yanova St., 603950 Nizhny Novgorod (Russian Federation)
The occurrence of kinetic plasma instabilities is studied in pulsed operation mode of a 14 GHz A-electron cyclotron resonance type electron cyclotron resonance ion source. It is shown that the temporal delay between the plasma breakdown and the appearance of the instabilities is on the order of 10-100 ms. The most important parameters affecting the delay are magnetic field strength and neutral gas pressure. It is demonstrated that kinetic instabilities limit the high charge state ion beam production in the unstable operating regime.
OSTI ID:
22482863
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 2 Vol. 87; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Similar Records

Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities
Journal Article · Sat Feb 14 23:00:00 EST 2015 · Review of Scientific Instruments · OSTI ID:22392353

Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating
Journal Article · Sat Aug 15 00:00:00 EDT 2015 · Physics of Plasmas · OSTI ID:22490094

H{sup -} extraction from electron-cyclotron-resonance-driven multicusp volume source operated in pulsed mode
Journal Article · Tue Mar 14 23:00:00 EST 2006 · Review of Scientific Instruments · OSTI ID:20778997