Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4927455· OSTI ID:22482704
; ; ; ; ; ; ; ; ; ; ; ; ;  [1];  [2];  [3];  [4]
  1. Brookhaven National Laboratory, Upton, New York 11793 (United States)
  2. University of Texas at El Paso, El Paso, Texas 79968 (United States)
  3. Korea University, Seoul 136-855 (Korea, Republic of)
  4. SUNY Binghamton, Vestal, New York 13902 (United States)

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe detectors coupled to a front-end readout application-specific integrated circuit (ASIC) for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6 × 6 × 15 mm{sup 3} detectors grouped into 3 × 3 sub-arrays of 2 × 2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays’ performance and reduction of their cost are possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

OSTI ID:
22482704
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 7 Vol. 86; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Cited By (1)

Efficient Charge Collection in Coplanar-Grid Radiation Detectors journal May 2018

Similar Records

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras
Journal Article · Tue Jul 28 00:00:00 EDT 2015 · Review of Scientific Instruments · OSTI ID:1239771

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors
Journal Article · Fri May 24 00:00:00 EDT 2019 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:1529886