Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission
Journal Article
·
· Review of Scientific Instruments
- Oak Ridge Associated Universities, Oak Ridge, Tennessee 37831 (United States)
- General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States)
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543-0451 (United States)
Neutral beam injection is used in tokamaks to heat, apply torque, drive non-inductive current, and diagnose plasmas. Neutral beam diagnostics need accurate spatial calibrations to benefit from the measurement localization provided by the neutral beam. A new technique has been developed that uses in situ measurements of neutral beam emission to determine the spatial location of the beam and the associated diagnostic views. This technique was developed to improve the charge exchange recombination (CER) diagnostic at the DIII-D tokamak and uses measurements of the Doppler shift and Stark splitting of neutral beam emission made by that diagnostic. These measurements contain information about the geometric relation between the diagnostic views and the neutral beams when they are injecting power. This information is combined with standard spatial calibration measurements to create an integrated spatial calibration that provides a more complete description of the neutral beam-CER system. The integrated spatial calibration results are very similar to the standard calibration results and derived quantities from CER measurements are unchanged within their measurement errors. The methods developed to perform the integrated spatial calibration could be useful for tokamaks with limited physical access.
- OSTI ID:
- 22482563
- Journal Information:
- Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 10 Vol. 86; ISSN 0034-6748; ISSN RSINAK
- Country of Publication:
- United States
- Language:
- English
Relative intensity calibration of the DIII-D charge-exchange recombination spectroscopy system using neutral beam injection into gas
|
journal | October 2018 |
Similar Records
Spatial calibration of a tokamak neutral beam diagnostic using in situ neutral beam emission
Measurement of neutral beam profiles at DIII-D
Measurement of neutral beam profiles at DIII-D. Revision 1
Journal Article
·
Mon Oct 19 20:00:00 EDT 2015
· Review of Scientific Instruments
·
OSTI ID:1371750
Measurement of neutral beam profiles at DIII-D
Conference
·
Mon Jun 01 00:00:00 EDT 1998
·
OSTI ID:639769
Measurement of neutral beam profiles at DIII-D. Revision 1
Conference
·
Sat Aug 01 00:00:00 EDT 1998
·
OSTI ID:639805