Purpose: A modification of the existing PVA-FX hydrogel has been made to investigate the use of a functionalised polymer in a Fricke gel dosimetry system to decrease Fe{sup 3+} diffusion. Methods: The chelating agent, xylenol orange, was chemically bonded to the gelling agent, polyvinyl alcohol (PVA) to create xylenol orange functionalised PVA (XO-PVA). A gel was created from the XO-PVA (20% w/v) with ferrous sulfate (0.4 mM) and sulfuric acid (50 mM). Results: This resulted in an optical density dose sensitivity of 0.014 Gy{sup −1}, an auto-oxidation rate of 0.0005 h{sup −1}, and a diffusion rate of 0.129 mm{sup 2} h{sup −1}; an 8% reduction compared to the original PVA-FX gel, which in practical terms adds approximately 1 h to the time span between irradiation and accurate read-out. Conclusions: Because this initial method of chemically bonding xylenol orange to polyvinyl alcohol has inherently low conversion, the improvement on existing gel systems is minimal when compared to the drawbacks. More efficient methods of functionalising polyvinyl alcohol with xylenol orange must be developed for this system to gain clinical relevance.
- OSTI ID:
- 22482419
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 12 Vol. 42; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Study of the absorption spectra of Fricke Xylenol Orange gel dosimeters
A least-squares error minimization approach in the determination of ferric ion diffusion coefficient of Fricke-infused dosimeter gels
Dose Measurements at Epithermal Beams of Research Reactors with Fricke Gel and Thermoluminescence Detectors
Conference
·
Wed Jul 01 00:00:00 EDT 2015
·
OSTI ID:22531276
A least-squares error minimization approach in the determination of ferric ion diffusion coefficient of Fricke-infused dosimeter gels
Journal Article
·
Thu Mar 31 23:00:00 EST 2005
· Medical Physics
·
OSTI ID:20634642
Dose Measurements at Epithermal Beams of Research Reactors with Fricke Gel and Thermoluminescence Detectors
Conference
·
Wed Jul 01 00:00:00 EDT 2015
·
OSTI ID:22531309