Title: Semiautomatic segmentation of liver metastases on volumetric CT images

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4932365· OSTI ID:22482378
 [1]; ;  [2]
  1. Department of Biomedical Engineering, Shanghai University of Medicine & Health Sciences, 101 Yingkou Road, Yang Pu District, Shanghai 200093 (China)
  2. Department of Radiology, Columbia University Medical Center, 630 West 168th Street, New York, New York 10032 (United States)

Purpose: Accurate segmentation and quantification of liver metastases on CT images are critical to surgery/radiation treatment planning and therapy response assessment. To date, there are no reliable methods to perform such segmentation automatically. In this work, the authors present a method for semiautomatic delineation of liver metastases on contrast-enhanced volumetric CT images. Methods: The first step is to manually place a seed region-of-interest (ROI) in the lesion on an image. This ROI will (1) serve as an internal marker and (2) assist in automatically identifying an external marker. With these two markers, lesion contour on the image can be accurately delineated using traditional watershed transformation. Density information will then be extracted from the segmented 2D lesion and help determine the 3D connected object that is a candidate of the lesion volume. The authors have developed a robust strategy to automatically determine internal and external markers for marker-controlled watershed segmentation. By manually placing a seed region-of-interest in the lesion to be delineated on a reference image, the method can automatically determine dual threshold values to approximately separate the lesion from its surrounding structures and refine the thresholds from the segmented lesion for the accurate segmentation of the lesion volume. This method was applied to 69 liver metastases (1.1–10.3 cm in diameter) from a total of 15 patients. An independent radiologist manually delineated all lesions and the resultant lesion volumes served as the “gold standard” for validation of the method’s accuracy. Results: The algorithm received a median overlap, overestimation ratio, and underestimation ratio of 82.3%, 6.0%, and 11.5%, respectively, and a median average boundary distance of 1.2 mm. Conclusions: Preliminary results have shown that volumes of liver metastases on contrast-enhanced CT images can be accurately estimated by a semiautomatic segmentation method.

OSTI ID:
22482378
Journal Information:
Medical Physics, Vol. 42, Issue 11; Other Information: (c) 2015 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Liver segmentation for CT images using GVF snake
Journal Article · Thu Dec 15 00:00:00 EST 2005 · Medical Physics · OSTI ID:22482378

Marker-controlled watershed for lymphoma segmentation in sequential CT images
Journal Article · Sat Jul 15 00:00:00 EDT 2006 · Medical Physics · OSTI ID:22482378

A new background distribution-based active contour model for three-dimensional lesion segmentation in breast DCE-MRI
Journal Article · Fri Aug 15 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22482378