Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

Conference ·
OSTI ID:2246800
 [1];  [1];  [2];  [2];  [2];  [2];  [2];  [3];  [4];  [4];
  1. Crytur USA
  2. Crytur, Czech Republic
  3. The Catholic Univ. of America, Washington, DC (United States)
  4. Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.
Research Organization:
Thomas Jefferson National Accelerator Facility, Newport News, VA (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Nuclear Physics (NP)
DOE Contract Number:
AC05-06OR23177
OSTI ID:
2246800
Report Number(s):
JLAB-PHY-23-3978; DOE/OR/23177-7315
Country of Publication:
United States
Language:
English

Similar Records

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal
Journal Article · Mon Mar 25 20:00:00 EDT 2024 · Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment · OSTI ID:2369561

A Comprehensive Survey of Readout Strategies for SiPMs Used in Nuclear Imaging Systems
Journal Article · Tue Jul 06 20:00:00 EDT 2021 · Photonics · OSTI ID:1852372

Design and Evaluation of a Pixelated PSD-capable Scintillator Detector with SiPM Readout
Technical Report · Sun Sep 01 00:00:00 EDT 2019 · OSTI ID:1560807

Related Subjects