Impact of Intrafraction and Residual Interfraction Effect on Prostate Proton Pencil Beam Scanning
Journal Article
·
· International Journal of Radiation Oncology, Biology and Physics
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania (United States)
Purpose: To quantitatively evaluate the impact of interplay effect and plan robustness associated with intrafraction and residual interfraction prostate motion for pencil beam scanning proton therapy. Methods and Materials: Ten prostate cancer patients with weekly verification CTs underwent pencil beam scanning with the bilateral single-field uniform dose (SFUD) modality. A typical field had 10-15 energy layers and 500-1000 spots. According to their treatment logs, each layer delivery time was <1 s, with average time to change layers of approximately 8 s. Real-time intrafraction prostate motion was determined from our previously reported prospective study using Calypso beacon transponders. Prostate motion and beam delivering sequence of the worst-case scenario patient were synchronized to calculate the “true” dose received by the prostate. The intrafraction effect was examined by applying the worst-case scenario prostate motion on the planning CT, and the residual interfraction effect was examined on the basis of weekly CT scans. The resultant dose variation of target and critical structures was examined to evaluate the interplay effect. Results: The clinical target volume (CTV) coverage was degraded because of both effects. The CTV D{sub 99} (percentage dose to 99% of the CTV) varied up to 10% relative to the initial plan in individual fractions. However, over the entire course of treatment the total dose degradation of D{sub 99} was 2%-3%, with a standard deviation of <2%. Absolute differences between SFUD, intensity modulate proton therapy, and one-field-per-day SFUD plans were small. The intrafraction effect dominated over the residual interfraction effect for CTV coverage. Mean dose to the anterior rectal wall increased approximately 10% because of combined residual interfraction and intrafraction effects, the interfraction effect being dominant. Conclusions: Both intrafraction and residual interfraction prostate motion degrade CTV coverage within a clinically acceptable level. One-field-per-day SFUD delivered twice is as robust as the bilateral SFUD plan treated daily over the course of treatment.
- OSTI ID:
- 22420512
- Journal Information:
- International Journal of Radiation Oncology, Biology and Physics, Journal Name: International Journal of Radiation Oncology, Biology and Physics Journal Issue: 5 Vol. 90; ISSN IOBPD3; ISSN 0360-3016
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of Intrafraction Prostate Motion on Proton Pencil Beam Scanning Delivery: A Quantitative Assessment
TH-C-BRD-11: Robustness of Pencil Beam Scanning Proton Therapy for Pelvic Cancer Under Anatomical Changes
Effects of Interfractional Motion and Anatomic Changes on Proton Therapy Dose Distribution in Lung Cancer
Journal Article
·
Tue Oct 01 00:00:00 EDT 2013
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:22267896
TH-C-BRD-11: Robustness of Pencil Beam Scanning Proton Therapy for Pelvic Cancer Under Anatomical Changes
Journal Article
·
Sun Jun 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22409848
Effects of Interfractional Motion and Anatomic Changes on Proton Therapy Dose Distribution in Lung Cancer
Journal Article
·
Sun Nov 30 23:00:00 EST 2008
· International Journal of Radiation Oncology, Biology and Physics
·
OSTI ID:21172497