skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Statistical Modeling Approach to Quantitative Analysis of Interobserver Variability in Breast Contouring

Journal Article · · International Journal of Radiation Oncology, Biology and Physics
 [1]; ; ; ; ; ;  [2]; ; ;  [1];  [3];  [1]
  1. Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)
  2. Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)
  3. Department of Radiation Oncology, Medical College of Wisconsin, Milwaukee, Wisconsin (United States)

Purpose: To develop a new approach for interobserver variability analysis. Methods and Materials: Eight radiation oncologists specializing in breast cancer radiation therapy delineated a patient's left breast “from scratch” and from a template that was generated using deformable image registration. Three of the radiation oncologists had previously received training in Radiation Therapy Oncology Group consensus contouring for breast cancer atlas. The simultaneous truth and performance level estimation algorithm was applied to the 8 contours delineated “from scratch” to produce a group consensus contour. Individual Jaccard scores were fitted to a beta distribution model. We also applied this analysis to 2 or more patients, which were contoured by 9 breast radiation oncologists from 8 institutions. Results: The beta distribution model had a mean of 86.2%, standard deviation (SD) of ±5.9%, a skewness of −0.7, and excess kurtosis of 0.55, exemplifying broad interobserver variability. The 3 RTOG-trained physicians had higher agreement scores than average, indicating that their contours were close to the group consensus contour. One physician had high sensitivity but lower specificity than the others, which implies that this physician tended to contour a structure larger than those of the others. Two other physicians had low sensitivity but specificity similar to the others, which implies that they tended to contour a structure smaller than the others. With this information, they could adjust their contouring practice to be more consistent with others if desired. When contouring from the template, the beta distribution model had a mean of 92.3%, SD ± 3.4%, skewness of −0.79, and excess kurtosis of 0.83, which indicated a much better consistency among individual contours. Similar results were obtained for the analysis of 2 additional patients. Conclusions: The proposed statistical approach was able to measure interobserver variability quantitatively and to identify individuals who tended to contour differently from the others. The information could be useful as feedback to improve contouring consistency.

OSTI ID:
22416566
Journal Information:
International Journal of Radiation Oncology, Biology and Physics, Vol. 89, Issue 1; Other Information: Copyright (c) 2014 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.; Country of input: International Atomic Energy Agency (IAEA); ISSN 0360-3016
Country of Publication:
United States
Language:
English

Similar Records

Target Volume Delineation for Partial Breast Radiotherapy Planning: Clinical Characteristics Associated with Low Interobserver Concordance
Journal Article · Sat Sep 01 00:00:00 EDT 2007 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22416566

Variability Among Breast Radiation Oncologists in Delineation of the Postsurgical Lumpectomy Cavity
Journal Article · Sun Apr 01 00:00:00 EDT 2007 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22416566

Automatic Segmentation of Whole Breast Using Atlas Approach and Deformable Image Registration
Journal Article · Wed Apr 01 00:00:00 EDT 2009 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22416566