Influence of the floating potential on micro-hollow cathode operation

Journal Article · · Physics of Plasmas
DOI:https://doi.org/10.1063/1.4922070· OSTI ID:22410457
 [1]; ;  [2]
  1. Department of Aerospace Engineering and Engineering Mechanics, The University of Texas at Austin, Austin, Texas 78712 (United States)
  2. Department of Physics, Technion, 32000 Haifa (Israel)
The influence of a keeper electrode with a floating potential on the operation of a micro-hollow cathode is studied using the two-dimensional particle-in-cell Monte Carlo collisions model. The floating potential is determined self-consistently, taking into account the electron and ion charges collected by the keeper and the potential induced by the plasma non-compensated space charge. It is shown that the parameters of the micro-hollow cathode operation vary significantly, according to whether the keeper potential is floating or has a specified constant value.
OSTI ID:
22410457
Journal Information:
Physics of Plasmas, Journal Name: Physics of Plasmas Journal Issue: 6 Vol. 22; ISSN PHPAEN; ISSN 1070-664X
Country of Publication:
United States
Language:
English

Similar Records

Instability of plasma plume of micro-hollow cathode discharge
Journal Article · Sat Nov 14 23:00:00 EST 2015 · Physics of Plasmas · OSTI ID:22489876

Two-dimensional model of orificed micro-hollow cathode discharge for space application
Journal Article · Thu Aug 15 00:00:00 EDT 2013 · Physics of Plasmas · OSTI ID:22220692

Rarefied xenon flow in orificed hollow cathodes
Journal Article · Mon Apr 14 20:00:00 EDT 2025 · Journal of Applied Physics · OSTI ID:2564373