Computerized analysis of coronary artery disease: Performance evaluation of segmentation and tracking of coronary arteries in CT angiograms
- Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109 (United States)
Purpose: The authors are developing a computer-aided detection system to assist radiologists in analysis of coronary artery disease in coronary CT angiograms (cCTA). This study evaluated the accuracy of the authors’ coronary artery segmentation and tracking method which are the essential steps to define the search space for the detection of atherosclerotic plaques. Methods: The heart region in cCTA is segmented and the vascular structures are enhanced using the authors’ multiscale coronary artery response (MSCAR) method that performed 3D multiscale filtering and analysis of the eigenvalues of Hessian matrices. Starting from seed points at the origins of the left and right coronary arteries, a 3D rolling balloon region growing (RBG) method that adapts to the local vessel size segmented and tracked each of the coronary arteries and identifies the branches along the tracked vessels. The branches are queued and subsequently tracked until the queue is exhausted. With Institutional Review Board approval, 62 cCTA were collected retrospectively from the authors’ patient files. Three experienced cardiothoracic radiologists manually tracked and marked center points of the coronary arteries as reference standard following the 17-segment model that includes clinically significant coronary arteries. Two radiologists visually examined the computer-segmented vessels and marked the mistakenly tracked veins and noisy structures as false positives (FPs). For the 62 cases, the radiologists marked a total of 10191 center points on 865 visible coronary artery segments. Results: The computer-segmented vessels overlapped with 83.6% (8520/10191) of the center points. Relative to the 865 radiologist-marked segments, the sensitivity reached 91.9% (795/865) if a true positive is defined as a computer-segmented vessel that overlapped with at least 10% of the reference center points marked on the segment. When the overlap threshold is increased to 50% and 100%, the sensitivities were 86.2% and 53.4%, respectively. For the 62 test cases, a total of 55 FPs were identified by radiologist in 23 of the cases. Conclusions: The authors’ MSCAR-RBG method achieved high sensitivity for coronary artery segmentation and tracking. Studies are underway to further improve the accuracy for the arterial segments affected by motion artifacts, severe calcified and noncalcified soft plaques, and to reduce the false tracking of the veins and other noisy structures. Methods are also being developed to detect coronary artery disease along the tracked vessels.
- OSTI ID:
- 22409579
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 8 Vol. 41; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis
Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography
Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications
Journal Article
·
Fri Aug 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22409870
Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography
Journal Article
·
Sat Oct 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22689261
Automatic multiscale enhancement and segmentation of pulmonary vessels in CT pulmonary angiography images for CAD applications
Journal Article
·
Fri Dec 14 23:00:00 EST 2007
· Medical Physics
·
OSTI ID:21032863