Denoised and texture enhanced MVCT to improve soft tissue conspicuity

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4894714· OSTI ID:22409490
;  [1];  [2];  [3]
  1. Department of Radiation Oncology, University of California, Los Angeles, California 90095 (United States)
  2. Department of Radiation Oncology, University of California, Los Angeles, California 90095 and Xidian University, Xi’An 710071 (China)
  3. Xidian University, Xi’An 710071 (China)
Purpose: MVCT images have been used in TomoTherapy treatment to align patients based on bony anatomies but its usefulness for soft tissue registration, delineation, and adaptive radiation therapy is limited due to insignificant photoelectric interaction components and the presence of noise resulting from low detector quantum efficiency of megavoltage x-rays. Algebraic reconstruction with sparsity regularizers as well as local denoising methods has not significantly improved the soft tissue conspicuity. The authors aim to utilize a nonlocal means denoising method and texture enhancement to recover the soft tissue information in MVCT (DeTECT). Methods: A block matching 3D (BM3D) algorithm was adapted to reduce the noise while keeping the texture information of the MVCT images. Following imaging denoising, a saliency map was created to further enhance visual conspicuity of low contrast structures. In this study, BM3D and saliency maps were applied to MVCT images of a CT imaging quality phantom, a head and neck, and four prostate patients. Following these steps, the contrast-to-noise ratios (CNRs) were quantified. Results: By applying BM3D denoising and saliency map, postprocessed MVCT images show remarkable improvements in imaging contrast without compromising resolution. For the head and neck patient, the difficult-to-see lymph nodes and vein in the carotid space in the original MVCT image became conspicuous in DeTECT. For the prostate patients, the ambiguous boundary between the bladder and the prostate in the original MVCT was clarified. The CNRs of phantom low contrast inserts were improved from 1.48 and 3.8 to 13.67 and 16.17, respectively. The CNRs of two regions-of-interest were improved from 1.5 and 3.17 to 3.14 and 15.76, respectively, for the head and neck patient. DeTECT also increased the CNR of prostate from 0.13 to 1.46 for the four prostate patients. The results are substantially better than a local denoising method using anisotropic diffusion. Conclusions: The authors showed that it is feasible to extract more soft tissue contrast information from the noisy MVCT images using a nonlocal means 3D block matching method in combination with saliency maps, revealing information that was originally unperceivable to human observers.
OSTI ID:
22409490
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 10 Vol. 41; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

SU-D-12A-02: DeTECT, a Method to Enhance Soft Tissue Contrast From Mega Voltage CT
Journal Article · Sun Jun 01 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22334016

High-dose MVCT image guidance for stereotactic body radiation therapy
Journal Article · Wed Aug 15 00:00:00 EDT 2012 · Medical Physics · OSTI ID:22098944

SU-E-I-58: Detecting Tumors with Extremely Low Contrast in CT Images
Journal Article · Sun Jun 01 00:00:00 EDT 2014 · Medical Physics · OSTI ID:22325162