Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals
Journal Article
·
· Journal of Medical Radiation Sciences (Print)
- The Prince Charles Hospital, Chermside, Queensland (Australia)
- Biomedical Technology Services, Health Services Support Agency, Queensland Health, Herston, Queensland (Australia)
- Allied Health Professions' Office of Queensland, Brisbane, Queensland (Australia)
- Royal Brisbane and Women's Hospital, Herston, Queensland (Australia)
- Princess Alexandra Hospital, Woolloongabba, Queensland (Australia)
- Cardiac Clinical Informatics Unit - Queensland Health, Herston, Queensland (Australia)
Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.
- OSTI ID:
- 22402357
- Journal Information:
- Journal of Medical Radiation Sciences (Print), Journal Name: Journal of Medical Radiation Sciences (Print) Journal Issue: 3 Vol. 61; ISSN 2051-3895
- Country of Publication:
- Australia
- Language:
- English
Similar Records
Patient radiation doses in interventional cardiology in the U.S.: Advisory data sets and possible initial values for U.S. reference levels
A pilot study exploring the possibility of establishing guidance levels in x-ray directed interventional procedures
Comparison of Patient Dose in Two-Dimensional Carotid Arteriography and Three-Dimensional Rotational Angiography
Journal Article
·
Mon Oct 15 00:00:00 EDT 2012
· Medical Physics
·
OSTI ID:22099047
A pilot study exploring the possibility of establishing guidance levels in x-ray directed interventional procedures
Journal Article
·
Thu Feb 14 23:00:00 EST 2008
· Medical Physics
·
OSTI ID:21036165
Comparison of Patient Dose in Two-Dimensional Carotid Arteriography and Three-Dimensional Rotational Angiography
Journal Article
·
Thu May 15 00:00:00 EDT 2008
· Cardiovascular and Interventional Radiology
·
OSTI ID:21094164