Negative hydrogen ion beam extraction from an AC heated cathode driven Bernas-type ion source

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.4916481· OSTI ID:22391460
A plasma grid structure was installed to a Bernas-type ion source used for ion implantation equipment. A negative hydrogen (H{sup −}) ion beam was extracted by an AC driven ion source by adjusting the bias to the plasma grid. The extracted electron current was reduced by positively biasing the plasma grid, while an optimum plasma grid bias voltage for negative ion beam extraction was found to be positive 3 V with respect to the arc chamber. Source operations with AC cathode heating show extraction characteristics almost identical to that with DC cathode heating, except a minute increase in H{sup −} current at higher frequency of cathode heating current.
OSTI ID:
22391460
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 1655; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Negative hydrogen ion beam extracted from a Bernas-type ion source
Journal Article · Mon Sep 26 00:00:00 EDT 2011 · AIP Conference Proceedings · OSTI ID:21611687

Fluctuation of an ion beam extracted from an AC filament driven Bernas-type ion source
Journal Article · Fri Feb 14 23:00:00 EST 2014 · Review of Scientific Instruments · OSTI ID:22254024

Negative Decaborane Ion Beam from ITEP Bernas Ion Source
Journal Article · Fri Aug 10 00:00:00 EDT 2007 · AIP Conference Proceedings · OSTI ID:21032665