Progress in the development of an H{sup −} ion source for cyclotrons
- Sumitomo Heavy Industries, Ltd., Tokyo (Japan)
- Fusion Research and Development Directorate, Japan Atomic Energy Agency, Aomori (Japan)
A multi-cusp DC H{sup −} ion source has been developed for cyclotrons in medical use. Beam optics of the H{sup −} ion beam is studied using a 2D beam trajectory code. The simulation results are compared with the experimental results obtained in the Mark I source, which has produced up to 16 mA H{sup −} ion beams. The optimum extraction voltages show good agreement between the calculation and the experimental results. A new ion source, Mark II source, is designed to achieve the next goal of producing an H{sup −} beam of 20 mA. The magnetic field configurations and the plasma electrode design are optimized for Cs-seeded operation. Primary electron trajectory simulation shows that primary electrons are confined well and the magnetic filter prevents the primary electrons from entering into the extraction region.
- OSTI ID:
- 22391422
- Journal Information:
- AIP Conference Proceedings, Vol. 1655, Issue 1; Conference: NIBS 2014: 4. International Symposium on Negative Ions, Beams and Sources, Garching (Germany), 6-10 Oct 2014; Other Information: (c) 2015 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of a compact filament-discharge multi-cusp H{sup -} ion source
Electron cyclotron resonance 140 mA D{sup +} beam extraction optimization for IFMIF EVEDA accelerator