Multiterawatt femtosecond laser system with kilohertz pulse repetition rate
- Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation)
The basic principles, layout and components are presented for a multiterawatt femtosecond laser system with a kilohertz pulse repetition rate f, based on their parametric amplification and laser amplification of picosecond radiation that pumps the stages of the parametric amplifier. The results of calculations for a step-by-step increase in the output power from the LBO crystal parametric amplifier channel up to the multiterawatt level are presented. By using the developed components in the pump channel of the laser system, the parameters of the regenerative amplifier with the output energy ∼1 mJ at the wavelength 1030 nm and with f = 1 kHz are experimentally studied. The optical scheme of the diode-pumped multipass cryogenic Yb:Y{sub 2}O{sub 3} laser ceramic amplifier is developed and its characteristics are determined that provide the output energy within the range 0.25 – 0.35 J. (lasers)
- OSTI ID:
- 22375915
- Journal Information:
- Quantum Electronics (Woodbury, N.Y.), Vol. 44, Issue 5; Other Information: Country of input: International Atomic Energy Agency (IAEA); ISSN 1063-7818