Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

SU-E-I-51: Use of Blade Sequences in Cervical Spine MR Imaging for Eliminating Motion, Truncation and Flow Artifacts

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4888000· OSTI ID:22325157
 [1]; ; ; ; ; ; ;  [2];  [3];  [4];  [5]; ;  [6];  [7];  [8]
  1. University of Texas Health Science Center, UTHSCSA, San Antonio, TX (United States)
  2. Technological Education Institute of Athens, Athens, Athens (Greece)
  3. General University Hospital ATTIKON, Athens, Athens (Greece)
  4. Health Center of Farkadona, Trikala (Greece)
  5. Center for Research and Technology of Thessaly, Trikala (Greece)
  6. IASO Thessalias Hospital, Larissa (Greece)
  7. Cancer Therapy and Research Center, San Antonio, TX (United States)
  8. University of Texas HSC SA, San Antonio, TX (United States)

Purpose: To assess the efficacy of the BLADE technique to eliminate motion, truncation, flow and other artifacts in Cervical Spine MRI compared to the conventional technique. To study the ability of the examined sequences to reduce the indetention and wrap artifacts, which have been reported in BLADE sagittal sequences. Methods: Forty consecutive subjects, who had been routinely scanned for cervical spine examination using four different image acquisition techniques, were analyzed. More specifically, the following pairs of sequences were compared: a) T2 TSE SAG vs. T2 TSE SAG BLADE and b) T2 TIRM SAG vs. T2 TIRM SAG BLADE. A quantitative analysis was performed using the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures. A qualitative analysis was also performed by two radiologists, who graded seven image characteristics on a 5-point scale (0:non-visualization; 1:poor; 2:average; 3:good; 4:excellent). The observers also evaluated the presence of image artifacts (motion, truncation, flow, indentation). Results: Based on the findings of the quantitative analysis, the ReCON values of the CSF (cerebrospinal fluid)/SC (spinal cord) between TIRM SAG and TIRM SAG BLADE were found to present statistical significant differences (p<0.001). Regarding motion and truncation artifacts, the T2 TSE SAG BLADE was superior compared to the T2 TSE SAG and the T2 TIRM SAG BLADE was superior compared to the T2 TIRM SAG. Regarding flow artifacts, T2 TIRM SAG BLADE eliminated more artifacts compared to the T2 TIRM SAG. Conclusion: The use of BLADE sequences in cervical spine MR examinations appears to be capable of potentially eliminating motion, pulsatile flow and trancation artifacts. Furthermore, BLADE sequences are proposed to be used in the standard examination protocols based on the fact that a significantly improved image quality could be achieved.

OSTI ID:
22325157
Journal Information:
Medical Physics, Journal Name: Medical Physics Journal Issue: 6 Vol. 41; ISSN 0094-2405; ISSN MPHYA6
Country of Publication:
United States
Language:
English

Similar Records

SU-E-I-67: Arachnoid Cysts: The Role of the BLADE Technique
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22494016

SU-E-I-62: Reduction of Susceptibility Artifacts by Increasing the Bandwidth (BW) and Echo Train Length (ETL)
Journal Article · Mon Jun 15 00:00:00 EDT 2015 · Medical Physics · OSTI ID:22494013

Optimal computed-tomographic techniques for cervical spine imaging
Journal Article · Thu Jul 01 00:00:00 EDT 1982 · Radiology; (United States) · OSTI ID:6843784