Diagnostics of ion beam generated from a Mather type plasma focus device
- Plasma Technology Research Centre, Department of Physics, Faculty of Science, University of Malaya (Malaysia)
Diagnostics of ion beam emission from a 3 kJ Mather-type plasma focus device have been performed for deuterium discharge at low pressure regime. Deuterium plasma focus was found to be optimum at pressure of 0.2 mbar. The energy spectrum and total number of ions per shot from the pulsed ion beam are determined by using biased ion collectors, Faraday cup, and solid state nuclear track detector CR-39. Average energy of the ion beam obtained is about 60 keV. Total number of the ions has been determined to be in the order of 10{sup 11} per shot. Solid state nuclear track detectors (SSNTD) CR39 are employed to measure the particles at all angular direction from end on (0°) to side on (90°). Particle tracks are registered by SSNTD at 30° to 90°, except the one at the end-on 0°.
- OSTI ID:
- 22266007
- Journal Information:
- AIP Conference Proceedings, Vol. 1588, Issue 1; Conference: 4. international meeting on frontiers in physics, Kuala Lumpur (Malaysia), 27-30 Aug 2013; Other Information: (c) 2014 AIP Publishing LLC; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-243X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Correlation of current drop, filling gas pressure, and ion beam emission in a low energy Mather-type plasma focus device
Temporal and spatial study of neon ion emission from a plasma focus device