Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy
- Departments of Radiology and Medicine, Columbia University, New York, New York 10032 (United States)
- Retired-Henry Ford Health System, Detroit, Michigan 48202 (United States)
- Department of Diagnostic and Interventional Imaging, The University of Texas Medical School at Houston, Houston, Texas 77030 (United States)
The 2012 Summer School of the American Association of Physicists in Medicine (AAPM) focused on optimization of the use of ionizing radiation in medical imaging. Day 2 of the Summer School was devoted to fluoroscopy and interventional radiology and featured seven lectures. These lectures have been distilled into a single review paper covering equipment specification and siting, equipment acceptance testing and quality control, fluoroscope configuration, radiation effects, dose estimation and measurement, and principles of flat panel computed tomography. This review focuses on modern fluoroscopic equipment and is comprised in large part of information not found in textbooks on the subject. While this review does discuss technical aspects of modern fluoroscopic equipment, it focuses mainly on the clinical use and support of such equipment, from initial installation through estimation of patient dose and management of radiation effects. This review will be of interest to those learning about fluoroscopy, to those wishing to update their knowledge of modern fluoroscopic equipment, to those wishing to deepen their knowledge of particular topics, such as flat panel computed tomography, and to those who support fluoroscopic equipment in the clinic.
- OSTI ID:
- 22251268
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 1 Vol. 41; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy
Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy
WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy
Journal Article
·
Tue Jan 14 23:00:00 EST 2014
· Medical Physics
·
OSTI ID:22251766
Operation logic and functionality of automatic dose rate and image quality control of conventional fluoroscopy
Journal Article
·
Fri May 15 00:00:00 EDT 2009
· Medical Physics
·
OSTI ID:22100492
WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy
Journal Article
·
Sun Jun 15 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22407868